Item # |
Analyzer |
Method of Detection |
Resolution |
Alarms |
Applications |
---|---|---|---|---|---|
309 Series /Asset/Multi-gas-Tech-Larger-Pic.jpg | N/A Portable Analyzer for Carbon Dioxide & Oxygen | Method of Detection N/A Electrochemical O2 sensor Infrared detector for CO2 | Resolution N/A 0.1% O2 and CO2 | Alarms N/A |
Applications
N/A
|
309A Series /Asset/Multi-gas-Tech-Larger-Pic.jpg | N/A Portable Analyzer for Carbon Dioxide & Oxygen in Agricultural Applications | Method of Detection N/A Electrochemical O2 sensor Infrared detector for CO2 | Resolution N/A 0.1% on % versions or 10 PPM on PPM versions | Alarms N/A |
Applications
N/A
|
312 Series /Asset/Multi-gas-Tech-Larger-Pic.jpg | N/A Portable Flue Gas Analyzer for Oxides of Nitrogen | Method of Detection N/A Customer replaceable electrochemical NO sensor | Resolution N/A 1 PPM NO | Alarms N/A NOx alarms with LED |
Applications
N/A
|
313 Series /Asset/Multi-gas-Tech-Larger-Pic.jpg | N/A Portable Flue Gas Analyzer for Oxides of Nitrogen | Method of Detection N/A Customer replaceable electrochemical nitric oxide and nitrogen dioxide sensors Expected life 2-3 year each | Resolution N/A 1 PPM on 0-2000 PPM; 10 PPM on higher ranges | Alarms N/A NO, NO2 or NOx alarms with LED |
Applications
N/A
|
3255 Series /Asset/Multi-gas-Tech-Larger-Pic.jpg | N/A Portable Analyzer for PPM Oxygen and Dew Point | Method of Detection N/A Customer replaceable O2 sensor, AlO2 Dew Point Sensor, T/C Cell for H2 | Resolution N/A ±1PPM O2, ±1°C or °F Dew Point, 0.1% H2 | Alarms N/A Optional |
Applications
N/A
|
340 Series /Asset/Multi-gas-Tech-Larger-Pic.jpg | N/A Portable Analyzer for Oxygen and Hydrogen | Method of Detection N/A Long-life electrochemical O2 sensor, temperature-compensated thermal conductivity (T/C) H2 cell cannot be burned out due to loss of flow or changing gases | Resolution N/A 0.1% on % ranges; 1 PPM on PPM O2 range | Alarms N/A O2 and H2 alarms with LED (optional) | Applications N/A Analysis of oxygen/hydrogen (O2/H2) in exothermic furnace atmospheres for copper, brass or steel anealing, neutral heating, sintering, glass metal beds or oxide coating of steel. |
350 Series /Asset/Multi-gas-Tech-Larger-Pic.jpg | N/A Portable Flue Gas Analyzer for Oxygen & Combustibles | Method of Detection N/A Catalytic oxidation detector for combustibles. Expected life is 2-3 years for each Customer replaceable electrochemical O2 sensor | Resolution N/A 0.1% O2 and combustibles | Alarms N/A |
Applications
N/A
|
352 Series /Asset/Multi-gas-Tech-Larger-Pic.jpg | N/A Portable Flue Gas Analyzer for Oxygen, Carbon Monoxide and Combustibles | Method of Detection N/A Catalytic oxidation detector for combustibles; expected life is 3-4 years for each Customer replaceable electrochemical O2 and CO sensors | Resolution N/A 0.1% O2, CO and combustibles | Alarms N/A |
Applications
N/A
|
360 Series /Asset/Multi-gas-Tech-Larger-Pic.jpg | N/A Portable Flue Gas Analyzer for Oxygen and Carbon Monoxide | Method of Detection N/A Customer replaceable electrochemical O2 and CO sensors | Resolution N/A 0.1% O2, 1 PPM CO | Alarms N/A High CO alarm with LED |
Applications
N/A
|
362 Series /Asset/Multi-gas-Tech-Larger-Pic.jpg | N/A Portable Flue Gas Analyzer for Oxygen, Carbon Monoxide and Oxides of Nitrogen | Method of Detection N/A Customer replaceable electrochemical O2, CO and NO sensor | Resolution N/A 0.1% O2; 1 PPM on CO and NOx | Alarms N/A |
Applications
N/A
|
375 Series /Asset/Multi-gas-Tech-Larger-Pic.jpg | N/A Portable Flue Gas Analyzer for Oxygen, Carbon Monoxide and Carbon Dioxide | Method of Detection N/A Customer replaceable electrochemical oxygen and CO sensors Solid state infra-red detector for CO2 | Resolution N/A 0.1% O2, 1 PPM on CO and CO2 | Alarms N/A |
Applications
N/A
|
376 Series /Asset/Multi-gas-Tech-Larger-Pic.jpg | N/A Portable Flue Gas Analyzer for Oxygen, Carbon Monoxide, Carbon Dioxide and Oxides of Nitrogen | Method of Detection N/A Customer replaceable electrochemical O2, CO and NO sensors Solid state infra-red detector for CO2 | Resolution N/A | Alarms N/A |
Applications
N/A
|
380 Series /Asset/Multi-gas-Tech-Larger-Pic.jpg | N/A Portable Tri Gas Analyzer for Hydrogen Purging | Method of Detection N/A Temperature compensated thermal conductivity (T/C) cell | Resolution N/A 0.1% of gas measured | Alarms N/A |
Applications
N/A
|
381 Series /Asset/Multi-gas-Tech-Larger-Pic.jpg | N/A Portable Tri-Gas Analyzer for H2 / N2 / Air Purging | Method of Detection N/A Thermal conductivity (T/C) cell, electrochemical O2 sensor | Resolution N/A 0.1% of gas measured | Alarms N/A | Applications N/A For checking purity of hydrogen (H2) in H2-cooled generators and synchronous converters. The Model 381 Series will also monitor the safe purging of H2 during shutdown or startup. This model is designed specifically for generators that are purged with nitrogen (N2) instead of carbon dioxide (CO2). |
382 Series /Asset/382K.jpg | N/A Portable Tri Gas Analyzer for Hydrogen Purging with separate O2 channel | Method of Detection N/A Thermal-conductivity (T/C) cell for H2; Electrochemical sensor for O2 | Resolution N/A 0.1% of gas measured | Alarms N/A |
Applications
N/A
|
402 Series /Asset/402AS-N4.jpg | N/A Automatic Sequencer | Method of Detection N/A No detection; sequences sample streams to (separately sold) analyzer for detection | Resolution N/A | Alarms N/A |
Applications
N/A
|
425 Series /Asset/Model-425N4.jpg | N/A Continuous Process Analyzer for Binary Gas Mixtures by Thermal Conductivity | Method of Detection N/A CH4 in N2, air, or CO2; SF6 in CO2, etc. CO2 in N2, H2, air, Ar, O2, He, etc O2 in Ar, CO2, He, H2, etc RTD-based TC cell can be used to measure almost any binary gas mixture such as H2 in N2, O2, air, SO2, Ar, He, NH3, etc | Resolution N/A 0.1% of gas to be measured | Alarms N/A High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating Low flow alarm |
Applications
N/A
|
436 Series /Asset/Multi-gas-Tech-Larger-Pic.jpg | N/A Tri-Gas Analyzer to Monitor Purity and Purging of Hydrogen Cooled Power Generator | Method of Detection N/A Temperature controlled thermal conductivity (T/C) cell, cannot be burned out due to loss of flow or changing gases | Resolution N/A ±0.1% of gas measured | Alarms N/A Alarm set points are field adjustable Alarms have front panel light for each alarm and SPST (normally energized) relay with 5A rating at 250VAC non-inductive load Dual alarms are provided for low H2 purity. Detector fail alarm also provided as standard |
Applications
N/A
|
5000 Series /Asset/Multi-gas-Tech-Larger-Pic.jpg | N/A Portable Flue Gas Analyzer for Any Combination of O2, CO, CO2, NOx, SO2and Stack Temperature | Method of Detection N/A Customer replaceable electrochemical O2, CO, SO2, and NO sensors Solid state infrared detector for CO2 | Resolution N/A ±0.1% CO2, 1 PPM, 1°F (1°C) | Alarms N/A |
Applications
N/A
|
501 Series /Asset/Multi-gas-Tech-Larger-Pic.jpg | N/A Continuous Multi-Gas Ambient Air Analyzer | Method of Detection N/A O2, CO, SO2, NO, NO2, H2, CL2, NH3 and H2S by electrochemical sensor, % RH by dielectric ceramic sensor, CO2 by infrared sensor | Resolution N/A 0.1% on % gas, 1 PPM on PPM gas | Alarms N/A One low O2 alarm and one high alarm for all other gases. Separate relay contacts for each gas with 5A rating. Separate indicator lights. Common 'Sonalert' audible alarm with reset button. Field-adjustable set points. |
Applications
N/A
|
600 Series /Asset/Multi-gas-Tech-Larger-Pic.jpg | N/A Portable Multi-Gas Ambient Air Analyzer | Method of Detection N/A O2, CO, SO2, NO, NO2, H2, CL2, NH3 and H2S by electrochemical sensor, % RH by dielectric ceramic sensor, CO2 by infrared sensor, combustibles by catalytic sensor | Resolution N/A 0.1% on % gas, 1 PPM on PPM gas | Alarms N/A Audible and visual alarms are optionally available as well as low battery and low flow |
Applications
N/A For ambient air or confined space monitoring for up to any four choices of O2, CO2, SO2, NO, NO2, H2, CO, Cl2, NH3, H2S, LEL combustibles, temperature, and % RH. |
7200 Series /Asset/7200-N4-Flue-Gas.jpg | N/A Continuous Flue Gas Analyzers | Method of Detection N/A % O2 by zirconia sensor when applicable % O2, 10-1000 PPM NO, NO2 CO and SO2 by electrochemical sensor CO2 >1000 PPM, % CO and SO2 by infrared detector Combustibles by catalytic combustibles detector with air 'make-up' system High accuracy % O2 by paramagnetic sensor | Resolution N/A 0.1% on %, 1 PPM on PPM | Alarms N/A High or low alarm contacts available for all gases and low flow |
Applications
N/A
|
7460 Series /Asset/Multi-gas-Tech-Larger-Pic.jpg | N/A Rugged Portable Analyzers for Engine Exhaust Emissions | Method of Detection N/A CO (low-range), NO, NO2 and O2 by long life electrochemical sensor. CO (standard range), CO2, and HC by infrared detector | Resolution N/A 0.1% on % gas, 1 PPM on PPM gas | Alarms N/A |
Applications
N/A
|
7900 Series /Asset/7900-N4-Ind-Multi.jpg | N/A Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems | Method of Detection N/A Dielectric ceramic sensor for Dew Point Electrochemical sensor for O2 NDIR infrared detector for CO, CO2, CH4 & NH3 Thermal conductivity cell for H2 | Resolution N/A 0.1%, 1 PPM, 1°F (Dew Point) | Alarms N/A High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating Low flow alarm |
Applications
N/A
|
7900P Series /Asset/7900P-Series.jpg | N/A Portable Gas Analyzer for Heat Treating and Other Hydrogen-Based Industrial Processes | Method of Detection N/A Customer may select one or more combinations of CO, CO2, H2, CH2, O2, or dew point | Resolution N/A 0.1% on % versions, 10 PPM on PPM versions | Alarms N/A |
Applications
N/A
|