New Call-to-action


Use "Search Items" button to combine all gases to be measured by one instrument.

Use "Compare Items" button to compare methods of detection.
1 - 25 of 27 | Results Per Page | View | Unit of Measure
1 2 

Item #

Analyzer

Method of Detection

Resolution

Alarms

Applications

N/A Portable Analyzer for Carbon Dioxide & Oxygen N/A Electrochemical O2 sensor Infrared detector for CO2 N/A 0.1% O2 and CO2 N/A N/A
    Analysis of Carbon Dioxide (CO2) and Oxygen (O2). For checking combustion efficiency, burner & control performance of furnaces, heaters and boilers in commercial, industrial and residential applications.
N/A Portable Analyzer for Carbon Dioxide & Oxygen in Agricultural Applications N/A Electrochemical O2 sensor Infrared detector for CO2 N/A 0.1% on % versions or 10 PPM on PPM versions N/A N/A
    For checking carbon dioxide (CO2) and oxygen (O2) in controlled atmosphere (C/A) storage rooms, welding gas mixtures, and other process applications.
N/A Portable Flue Gas Analyzer for Oxides of Nitrogen N/A Customer replaceable electrochemical NO sensor N/A 1 PPM NO N/A NOx alarms with LED N/A
    Analysis of oxides of nitrogen (NOx) as nitric oxide (NO) for boiler, furnace, or engine exhaust.
N/A Portable Flue Gas Analyzer for Oxides of Nitrogen N/A Customer replaceable electrochemical nitric oxide and nitrogen dioxide sensors Expected life 2-3 year each N/A 1 PPM on 0-2000 PPM; 10 PPM on higher ranges N/A NO, NO2 or NOx alarms with LED N/A
    Analysis of oxides of nitrogen (NOx) such as nitric oxide (NO) and/or nitrogen dioxide (NO2). For boiler, furnace, or engine exhaust monitoring and analysis.
N/A Portable Analyzer for PPM Oxygen and Dew Point N/A Customer replaceable O2 sensor, AlO2 Dew Point Sensor, T/C Cell for H2 N/A ±1PPM O2, ±1°C or °F Dew Point, 0.1% H2 N/A Optional N/A
    Designed for use on low oxygen (O2) and low dew point (DP) process gases
N/A Portable Analyzer for Oxygen and Hydrogen N/A Long-life electrochemical O2 sensor, temperature-compensated thermal conductivity (T/C) H2 cell cannot be burned out due to loss of flow or changing gases N/A 0.1% on % ranges; 1 PPM on PPM O2 range N/A O2 and H2 alarms with LED (optional) N/A Analysis of oxygen/hydrogen (O2/H2) in exothermic furnace atmospheres for copper, brass or steel anealing, neutral heating, sintering, glass metal beds or oxide coating of steel.
N/A Portable Flue Gas Analyzer for Oxygen & Combustibles N/A Catalytic oxidation detector for combustibles. Expected life is 2-3 years for each Customer replaceable electrochemical O2 sensor N/A 0.1% O2 and combustibles N/A N/A
    Analysis of oxygen (O2) and combustibles. For checking the combustion efficiency, and burner & control performance of furnaces, heaters, and boilers. May be used in commercial, industrial, and residential settings.
N/A Portable Flue Gas Analyzer for Oxygen, Carbon Monoxide and Combustibles N/A Catalytic oxidation detector for combustibles; expected life is 3-4 years for each Customer replaceable electrochemical O2 and CO sensors N/A 0.1% O2, CO and combustibles N/A N/A
    Analysis of oxygen (O2), carbon dioxide (CO) and combustibles. For checking the combustion efficiency, and burner & control performance of furnaces, heaters, and boilers. May be used in commercial, industrial, and residential settings.
N/A Portable Flue Gas Analyzer for Oxygen and Carbon Monoxide N/A Customer replaceable electrochemical O2 and CO sensors N/A 0.1% O2, 1 PPM CO N/A High CO alarm with LED N/A
    Analysis of oxygen (O2) and carbon monoxide (CO). For checking combustion efficiency, air infiltration, and burner & control performance of furnaces, heaters and, boilers. May be used in commercial, industrial and residential settings.
N/A Portable Flue Gas Analyzer for Oxygen, Carbon Monoxide and Oxides of Nitrogen N/A Customer replaceable electrochemical O2, CO and NO sensor N/A 0.1% O2; 1 PPM on CO and NOx N/A N/A
    Analysis of oxygen (O2), carbon monoxide (CO), and oxides of nitrogen (NOx as NO). For checking combustion efficiency, air infiltration, NOx emissions, and burner & control performance of furnaces, heaters, and boilers. May be used in commercial, industrial and residential applications.
N/A Portable Flue Gas Analyzer for Oxygen, Carbon Monoxide and Carbon Dioxide N/A Customer replaceable electrochemical oxygen and CO sensors Solid state infra-red detector for CO2 N/A 0.1% O2, 1 PPM on CO and CO2 N/A N/A
    Analysis of oxygen (O2), carbon monoxide (CO), and carbon dioxide (CO2). For checking the combustion efficiency and burner & control performance of furnaces, heaters, and boilers. May be used in commercial, industrial, and residential settings.
N/A Portable Flue Gas Analyzer for Oxygen, Carbon Monoxide, Carbon Dioxide and Oxides of Nitrogen N/A Customer replaceable electrochemical O2, CO and NO sensors Solid state infra-red detector for CO2 N/A N/A N/A
    Analysis of oxygen (O2), carbon monoxide (CO), carbon dioxide (CO2) and oxides of nitrogen (NOx as NO). For checking the combustion efficiency and burner & control performance of furnaces, heaters, and boilers. May be used in commercial, industrial, and residential settings.
N/A Portable Tri Gas Analyzer for Hydrogen Purging N/A Temperature compensated thermal conductivity (T/C) cell N/A 0.1% of gas measured N/A N/A
    For checking purity of hydrogen (H2) in H2-cooled generators and synchronous converters. The Model 380 Series will also monitor the safe purging of H2 during shut down.
N/A Portable Tri-Gas Analyzer for H2 / N2 / Air Purging N/A Thermal conductivity (T/C) cell, electrochemical O2 sensor N/A 0.1% of gas measured N/A N/A For checking purity of hydrogen (H2) in H2-cooled generators and synchronous converters. The Model 381 Series will also monitor the safe purging of H2 during shutdown or startup. This model is designed specifically for generators that are purged with nitrogen (N2) instead of carbon dioxide (CO2).
N/A Portable Tri Gas Analyzer for Hydrogen Purging with separate O2 channel N/A Thermal-conductivity (T/C) cell for H2; Electrochemical sensor for O2 N/A 0.1% of gas measured N/A N/A
    For checking purity of hydrogen (H2) in H2-cooled generators and synchronous converters. The Model 380 Series will also monitor the safe purging of H2 during shut down.
N/A Automatic Sequencer N/A No detection; sequences sample streams to (separately sold) analyzer for detection N/A N/A N/A
    Allows a single Nova gas analyzer to be time shared over many sample points. It can be controlled locally or remotely. Applications include multiple greenhouses, mushroom farms, multiple flue gas ducts, multiple landfill well or area sampling.
N/A Continuous Process Analyzer for Binary Gas Mixtures by Thermal Conductivity N/A CH4 in N2, air, or CO2; SF6 in CO2, etc. CO2 in N2, H2, air, Ar, O2, He, etc O2 in Ar, CO2, He, H2, etc RTD-based TC cell can be used to measure almost any binary gas mixture such as H2 in N2, O2, air, SO2, Ar, He, NH3, etc N/A 0.1% of gas to be measured N/A High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating Low flow alarm N/A
    For continuous analysis of many binary gas mixtures comprised of H2, CO2, O2, CH4, SO2, Ar, He, NH3, SF6, air, and others. Applications include heat treating atmospheres, welding gas mixtures, blanketing gas mixtures, ammonia synthesis, leak detection, purge monitoring, flue gas, magnesium blanketing by SF6 and others.
N/A Tri-Gas Analyzer to Monitor Purity and Purging of Hydrogen Cooled Power Generator N/A Temperature controlled thermal conductivity (T/C) cell, cannot be burned out due to loss of flow or changing gases N/A ±0.1% of gas measured N/A Alarm set points are field adjustable Alarms have front panel light for each alarm and SPST (normally energized) relay with 5A rating at 250VAC non-inductive load Dual alarms are provided for low H2 purity. Detector fail alarm also provided as standard N/A
    For continuous analysis of hydrogen (H2) purity and for purge monitoring of hydrogen-cooled generators and synchronous converters.
N/A Portable Flue Gas Analyzer for Any Combination of O2, CO, CO2, NOx, SO2and Stack Temperature N/A Customer replaceable electrochemical O2, CO, SO2, and NO sensors Solid state infrared detector for CO2 N/A ±0.1% CO2, 1 PPM, 1°F (1°C) N/A N/A
    Analysis of carbon Monoxide (CO), carbon dioxide (CO2), sulfur dioxide (SO2), and oxide of nitrogen (NOx) emissions. For checking combustion efficiency, burner & control performance, and detection of air infiltration on furnaces, heaters and boilers. May be used in commercial, industrial and residential settings.
N/A Continuous Multi-Gas Ambient Air Analyzer N/A O2, CO, SO2, NO, NO2, H2, CL2, NH3 and H2S by electrochemical sensor, % RH by dielectric ceramic sensor, CO2 by infrared sensor N/A 0.1% on % gas, 1 PPM on PPM gas N/A One low O2 alarm and one high alarm for all other gases. Separate relay contacts for each gas with 5A rating. Separate indicator lights. Common 'Sonalert' audible alarm with reset button. Field-adjustable set points. N/A
    For simultaneous analysis and alarm of up to four of any combination of O2 deficiency, CO2, SO2, NO, NO2, H2, CO, CL2, NH3, H2S, % RH, and temperature of ambient air.
N/A Portable Multi-Gas Ambient Air Analyzer N/A O2, CO, SO2, NO, NO2, H2, CL2, NH3 and H2S by electrochemical sensor, % RH by dielectric ceramic sensor, CO2 by infrared sensor, combustibles by catalytic sensor N/A 0.1% on % gas, 1 PPM on PPM gas N/A Audible and visual alarms are optionally available as well as low battery and low flow N/A For ambient air or confined space monitoring for up to any four choices of O2, CO2, SO2, NO, NO2, H2, CO, Cl2, NH3, H2S, LEL combustibles, temperature, and % RH.

N/A Continuous Flue Gas Analyzers N/A % O2 by zirconia sensor when applicable % O2, 10-1000 PPM NO, NO2 CO and SO2 by electrochemical sensor CO2 >1000 PPM, % CO and SO2 by infrared detector Combustibles by catalytic combustibles detector with air 'make-up' system High accuracy % O2 by paramagnetic sensor N/A 0.1% on %, 1 PPM on PPM N/A High or low alarm contacts available for all gases and low flow N/A
    Continuous analysis of flue gas for any combination and range of O2, CO, CO2, SO2, NOx (NO or NO + NO2) or combustibles from combustion processes.
N/A Rugged Portable Analyzers for Engine Exhaust Emissions N/A CO (low-range), NO, NO2 and O2 by long life electrochemical sensor. CO (standard range), CO2, and HC by infrared detector N/A 0.1% on % gas, 1 PPM on PPM gas N/A N/A
    For checking engine exhaust emissions for diesel, gasoline, propane, or natural gas powered 2 and 4 cycle engines. Analysis of Carbon Monoxide (CO), Hydrocarbons (HC’s), Carbon dioxide (CO2), Oxygen (O2), Oxides of Nitrogen (NOx), Nitric Oxide (NO), and Nitrogen dioxide (NO2).
N/A Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems N/A Dielectric ceramic sensor for Dew Point Electrochemical sensor for O2 NDIR infrared detector for CO, CO2, CH4 & NH3 Thermal conductivity cell for H2 N/A 0.1%, 1 PPM, 1°F (Dew Point) N/A High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating Low flow alarm N/A
    For continuous monitoring of any combination of heat treat atmosphere gases such as Oxygen (O2), Methane (CH4), Carbon Dioxide (CO2), Carbon Monoxide (CO), Hydrogen (H2), Ammonia (NH3), and Dew Point (standard and low ranges). Also available for other industrial process gases.
N/A Portable Gas Analyzer for Heat Treating and Other Hydrogen-Based Industrial Processes N/A Customer may select one or more combinations of CO, CO2, H2, CH2, O2, or dew point N/A 0.1% on % versions, 10 PPM on PPM versions N/A N/A
    For monitoring heat treating atmosphere gases in any combination of carbon monoxide (CO), carbon dioxide (CO2), methane (CH4), hydrogen (H2), oxygen (O2) and dew point. Also available for other industrial processes that include hydrogen.
1 - 25 of 27 | Results Per Page | View | Unit of Measure
1 2 
View Our
Product Catalog
Have a question?
Contact Us
Ready to get started?
Request Quote