In operation, a built-in sample pump draws in the flue gas sample through the S.S. probe, 12 ft sample hose, condensate removal filter, secondary filter and flow meter then on to the O2 sensor and CO2 detector. The detected gases are displayed on separate LCD digital meters which have a switchable backlight for use in dark areas.
The 309 can optionally indicate stack temperatrue (309T) for doing fuel efficiency calculations. The temperature sensor is built into the sampling probe. Efficiency charts for each fuel are provided.
A rechargeable battery provides enough power for about 8 hours of continuous operation and the analyzer can be used while it is being recharged. A red LED tells when to recharge and a green LED verifies that it is receiving recharging power. The recharger is included.
Method of Detection |
N/A Electrochemical O2 sensor Infrared detector for CO2 |
Ranges Available |
N/A
0-5000 ppm; 0-1%; 0-10%; 0-20%; 0-50%; 0-100% CO2 0-25% O2 |
Resolution |
N/A 0.1% O2 and CO2 |
Accuracy & Repeatability |
N/A Within ±2% full scale |
Drift |
N/A Within 1% full scale per 8 hours of continuous operation |
Response Time (T-90) |
N/A O2 less than 10 seconds; CO2 less than 30-40 seconds to T-90 |
Ambient Temperature Range |
N/A 4 to 49 ºC40 to 120 ºF |
Linearity |
N/A ±1.0% of full scale |
Size & Weight |
N/A K Style - 14" L x 10 1/2" W x 6" H @ 12 lbs ( 36 x 27 x 15 cm @ 5.5 kg) WP Style - 11 1/2" L x 8" W x 7 1/4" H @ 8 lbs (29 x 20 x 18 cm @ 3.6 kg) |
Power |
N/A AC/DC Operation, 115 VAC, 60 Hz for recharging |
Output Options |
N/A 0-1 VDC 4-20 mA |
Unique Applications |
N/A
|
Primary Gas to be Measured |
N/A Carbon Dioxide (CO2) Oxygen (O2) |
Industry Type |
N/A Flue Gas or Emissions |
N/A
|
N/A
|
N/A
|
N/A
|
Product Catalog