Sample gas is drawn into the analyzer from the sampling probe heated filter or sample pre-conditioner, then pumped through a condensate removal system. Any condensate formed is collected then automatically purged. Next, the dried sample gas is filtered again, then flows through a pressure regulator, PTFE liquid blocker, calibration gas valves, low flow switch, flow meter then on to the gas detectors. An optional vacuum switch at the pump inlet warns if the pre-filter is becoming plugged up.
The 7200 Series analyzers are available in any combination of O2, CO, CO2, NOx (as NO or NO + NO2), SO2, or combustibles, with separate digital readouts and outputs for each. Special sampling probes are available for high temperature applications up to 3200°F (1760°C). The 7200 Series is multi-sample point capable (consult Nova).
Method of Detection |
N/A % O2 by zirconia sensor when applicable % O2, 10-1000 PPM NO, NO2 CO and SO2 by electrochemical sensor CO2 >1000 PPM, % CO and SO2 by infrared detector Combustibles by catalytic combustibles detector with air 'make-up' system High accuracy % O2 by paramagnetic sensor |
Ranges Available |
N/A 0-100 PPM to 0-5% SO2 0-100 to 0-100% CO 0-100 to 0-5000 PPM NO 0-100 to 0-800 PPM NO2 0-2, 0-5, 0-10% Combustibles 0-20% CO2 0-5 to 0-25% O2 |
Resolution |
N/A 0.1% on %, 1 PPM on PPM |
Accuracy & Repeatability |
N/A ±1-2% of full scale - depending on gas measured and range |
Drift |
N/A Less than 2% of full scale per month |
Response Time (T-90) |
N/A 20-30 seconds to 90% of step change |
Ambient Temperature Range |
N/A 32 to 122°F (0 to 50°C) @ 5-95% RH non-condensing. Lower temperatures (-5°F, -20°C) with Cold Weather Package. ºC |
Linearity |
N/A ±1% of full scale |
Size & Weight |
N/A Dimensions and weight will vary with configurations selected |
Power |
N/A 115 VAC, 60 Hz 220 VAC, 50 Hz |
Output Options |
N/A OP1 - 4-20 mA non-isolated OP2 - 4-20 mA isolated OP3 - 0-5 V OP4 - 0-10 V OP5 - RS-485 OP6 - Modbus |
Alarms |
N/A High or low alarm contacts available for all gases and low flow |
Unique Applications |
N/A
|
Primary Gas to be Measured |
N/A Oxygen (O2) |
Code Numbers for Gases Measured |
N/A O2 by electrochemical sensor |
Sampling System |
N/A Std SS probe with unheated pre-filter (Std. probe 3/8" O.D. x 18") (9.5 x 460 mm) |
Sample Points |
N/A 1 Sample point (no sequencing) |
Display Type |
N/A D1 - LED display (s) - Manual potentiometer calibration D2 - LED display (s) - Manual push-button calibration D3 - Microprocessor controller with single graphic display. Allows auto sequencing, RS-485 output, 'CAL NOW' and one-step D4 - Same as D3 but with full auto-calibration |
Industry Type |
N/A Flue Gas or Emissions |
N/A
|
N/A
|
N/A
|
Product Catalog
Contact Us
Request Quote