In operation, a built in sample pump draws in the gas sample through the S.S. probe, 12 ft sample hose, condensate removal filter, secondary filter and flowmeter then on to the NO sensor. The detected NO is displayed on a LCD digital meter which has a switchable backlight for use in dark areas.
The rechargeable battery provides enough power for about 20 hours of continuous operation and the analyzer can be used while it is being recharged. A red LED tells when to recharge and a green LED verifies that it is receiving recharging power. The recharger is included.
Method of Detection |
N/A Customer replaceable electrochemical NO sensor |
Ranges Available |
N/A 0-2000 PPM NOx (as NO) |
Resolution |
N/A 1 PPM NO |
Accuracy & Repeatability |
N/A Better than 2% full scale |
Drift |
N/A Within 1% full scale per 8 hours of continuous operation |
Response Time (T-90) |
N/A 20-30 seconds for 90% of step change |
Ambient Temperature Range |
N/A 12 to 49 ºC55 to 120 ºF |
Linearity |
N/A ±2% of full scale |
Size & Weight |
N/A K Style: 14"L x 10 1/2" W x 6" H @ 12 lbs ( 36 x 27 x 15 cm @ 5.5 kg) WP Style: 11 1/2" L x 8" W x 7 1/4" H @ 8 lbs (29 x 20 x 18 cm @ 3.6 kg) |
Power |
N/A AC/DC Operation, 115 VAC, 60 Hz for recharging (220 VAC 50Hz available) |
Output Options |
N/A 4-20 mA or 0-1 VDC |
Alarms |
N/A NOx alarms with LED |
Unique Applications |
N/A
Note: For proper operation, the sample gas should also contain a small amount of oxygen. All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova. In many cases, we are able to build an analyzer specific to your needs. |
Primary Gas to be Measured |
N/A Oxides of Nitrogen (NOx) |
Industry Type |
N/A Flue Gas or Emissions |
N/A
|