In operation, a built in sample pump draws in the flue gas sample through the S.S. probe, 12 ft. sample hose, condensate removal filter, secondary filter, flow meter, and then on to the three sensors. The detected O2, CO, and NO are displayed on separate LCD digital meters, which have a switchable backlight for use in dark areas. The analyzer can be operated for long periods unattended.
The Nova 362 can also optionally indicate net stack temperature for doing fuel efficiency calculations (362T). The temperature sensor is built into the sampling probe. Efficiency charts for each fuel are provided.
A rechargeable 'gel cell' battery provides enough power for about 16 hours of continuous operation and the analyzer can be used while it is being recharged. A red LED indicates when to recharge and a green LED verifies that it is receiving recharging power. The battery recharger is included with the analyzer. The rugged dust-tight and water resistant case is ideal for use in harsh environments.
Method of Detection |
N/A Customer replaceable electrochemical O2, CO and NO sensor |
Ranges Available |
N/A 0-200 to 0-2000 PPM NOx (as NO); 0-1800°F (0-1000°C) net stack temperature (362T) 0-25.0% O2; 0-2000 PPM to 0-4.00% CO (switch selectable) |
Resolution |
N/A 0.1% O2; 1 PPM on CO and NOx |
Accuracy & Repeatability |
N/A <1% of O2; ± 10 PPM CO; ± 3 PPM NOx |
Drift |
N/A ±2% of full scale per 8 hours of continuous operation |
Response Time (T-90) |
N/A 10-12 seconds for O2; 20-30 seconds for CO and NOx |
Ambient Temperature Range |
N/A 0 to 40 ºC32 to 105 ºF |
Linearity |
N/A ±1% of full scale of each gas measured |
Size & Weight |
N/A K Style: 10 1/2" W x 14" L x 6" H @ 13 lbs (27 x 35 x 15 cm @ 6 kg) WP Style: 18" W x 12" L x 5 1/4" H @ 13 lbs (45 x 30 x 13 cm @ 6 kg) |
Power |
N/A AC/DC Operation, 115 VAC 60 Hz for recharging (Other voltages available.) |
Output Options |
N/A 4-20 mA or 0-1 VDC |
Unique Applications |
N/A All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova. In many cases, we are able to build an analyzer specific to your needs. |
Primary Gas to be Measured |
N/A Carbon Monoxide (CO) Oxides of Nitrogen (NOx) Oxygen (O2) |
Industry Type |
N/A Flue Gas or Emissions |
N/A
|
N/A
|
N/A
|
N/A
|
Product Catalog
Contact Us
Request Quote