Print Back
Process Carbon Monoxide (CO) analyzer (using an infrared detector) from the Nova FLEXI-NOVA Series Platform, designed for light-duty continuous gas measurements.
Continuous Process Gas Analyzers
Unit of Measure
Items Continuous Process Gas Analyzers
Model 481N4
Model 481N4, Carbon Monoxide Analyzer (infrared), Wall Mounted NEMA4 (IP65) Enclosure Rating
N4N7 cabinets
Model 481N4N7
Model 481N4N7, Carbon Monoxide Analyzer (infrared), ex-proof sensor housing with NEMA4 wall-mount control cabinet (two separate enclosures)
N7MC generic
Model 481N7MC
Model 481N7MC, Carbon Monoxide Analyzer (infrared), Wall Mounted NEMA7 UL/CSA Explosion-proof with Non-intrusive Magnetic Calibration, Class 1 Div 1 Group BCD
RMN7 21
Model 481RMN7
Model 481RMN7, Carbon Monoxide Analyzer (infrared), ex-proof sensor housing with rack mount control cabinet (two separate enclosures)
Purged cabinets
Model 481 D1 or D2
Model 481 D1 or D2, Carbon Monoxide Analyzer (infrared) - 481 Series; NEMA 4 cabinet with Hazardous Area Purge System
Method of Detection N/A Single cell NDIR with no moving parts N/A Single cell NDIR with no moving parts N/A NDIR infrared detector for CO N/A NDIR infrared detector for CO N/A Single cell NDIR with no moving parts
Ranges Available N/A High ranges - any from 0-40 to 0-100% CO Standard ranges - 0-1.00, 2.00, 5.00, 10, 30% CO
Accuracy & Repeatability N/A ±1-3% of full scale, depending on measurement range and application
Drift N/A Usually 2% of full scale per month or less, depending on range and application
Response Time (T-90) N/A Usually 20-30 seconds to 90% step change, depending on range and application
Ambient Temperature Range N/A 40 to 104°F (4 to 40°C)
Linearity N/A Usually ±1.5% of full scale, depending on range and application
Size & Weight N/A NEMA 4: 51H x 41W x 26D cm (20"H x 16"W x 10"D) RACK MOUNT: 22H x 48W x 47D cm (8.7"H x 19"W x 16"D) N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) NEMA 4: 51H x 41W x 26D cm (20"H x 16"W x 10"D) N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) RACK MOUNT: 22H x 48W x 47D cm (8.7"H x 19"W x 16"D) N/A NEMA 4: 61H x 51W x 31D cm (24"H x 20"W x 12"D) (not including purge panel & vent)
Output Options N/A 4-20 mA into 500 ohms non-isolated standard Isolated 4-20 mA, RS232, RS485, serial outputs N/A 4-20 mA into 500 ohms non-isolated standard Isolated 4-20 mA, RS232, RS485, serial outputs N/A 4-20 mA into 500 ohms non-isolated standard Isolated 4-20 mA, RS232, RS485 serial outputs N/A 4-20 mA into 500 ohms non-isolated standard Isolated 4-20 mA, RS232, RS485 serial outputs N/A 4-20 mA into 500 ohms non-isolated standard Isolated 4-20 mA, RS232, RS485 serial outputs
Alarms N/A High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating Low flow alarm
Options N/A Cabinet coolers can be fitted to most models Hi/Low gas, Low Flow alarms available High temperature filters and probes Isolated 4-20 mA, RS232, RS485, serial outputs Light duty sample conditioning systems available for removal of moisture and/or dust N/A Hi/Low gas, Low Flow alarms available Isolated 4-20 mA, RS232, RS485, serial outputs N/A Hi/Low gas, Low Flow alarms available Isolated 4-20 mA, RS232, RS485 serial outputs N/A Hi/Low gas, Low Flow alarms available Isolated 4-20 mA, RS232, RS485 serial outputs N/A Cabinet coolers can be fitted to most models Cabinet purge system available for use in hazardous areas Hi/Low gas, Low Flow alarms available High temperature filters and probes Isolated 4-20 mA, RS232, RS485 serial outputs Light duty sample conditioning systems available for removal of moisture and/or dust
Analyzer Type N/A CO analyzer (IR) N/A CO analyzer (IR) N/A CO analyzer N/A CO analyzer N/A CO analyzer
Hazardous Area Rating Options N/A General Purpose, Non-Hazardous N/A Control Cabinet - General Purpose, Non-Hazardous Detector Cabinet - NEMA7 Class 1 Division 1 Groups BCD N/A Class 1, Div 1, Grp A-D Hazardous Area Rating N/A Control Cabinet - General Purpose, Non-Hazardous Detector Cabinet - NEMA7 Class 1 Division 1 Groups BCD N/A Class 1 Div 2 or Class 1 Div 1 Hazardous Area Ratings available