For clean process measurements of percent-level CO gas by infrared detector.
All sensors / detectors are temperature-controlled or temperature-compensated for maximum analytical stability. Easy calibration using touch-screen controls. Serial Output Package allows connection & data-logging to personal computers via a choice of USB / RS-232 / RS-485.
Cabinet: Wall Mounted NEMA7 UL/CSA Explosion-proof with Non-intrusive Magnetic Calibration, Class 1 Div 1 Group BCD
Specifications
Method of Detection |
N/A NDIR infrared detector for CO |
Ranges Available |
N/A High ranges - any from 0-40 to 0-100% CO Standard ranges - 0-1.00, 2.00, 5.00, 10, 30% CO |
Resolution |
N/A 0.1% on most % ranges |
Accuracy & Repeatability |
N/A ±1-3% of full scale, depending on measurement range and application |
Drift |
N/A Usually 2% of full scale per month or less, depending on range and application |
Response Time (T-90) |
N/A Usually 20-30 seconds to 90% step change, depending on range and application |
Ambient Temperature Range |
N/A 40 to 104°F (4 to 40°C) |
Linearity |
N/A Usually ±1.5% of full scale, depending on range and application |
Size & Weight |
N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) |
Power |
N/A 115 VAC, 60 Hz 220 VAC, 50 Hz |
Output Options |
N/A 4-20 mA into 500 ohms non-isolated standard Isolated 4-20 mA, RS232, RS485 serial outputs |
Alarms |
N/A High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating Low flow alarm |
Analyzer Type |
N/A CO analyzer |
Hazardous Area Rating Options |
N/A Class 1, Div 1, Grp A-D Hazardous Area Rating |
Applications
N/A Light-duty analyzers for applications or environments that are less intensive. For continuous analysis of percent levels of carbon monoxide (CO) in process gas streams using an infrared detector. |
Features
N/A
|
Unique Applications
N/A The FlexiNova 481 Series analyzers are designed for detection of CO in non-corrosive gas streams. All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova at 1-800-295-3771. In many cases, we are able to build an analyzer specific to your needs. |
Product Catalog
Contact Us
Request Quote