Home
About Us
About NOVA
What's new at NOVA
About Tenova Goodfellow
About the Tenova Group
Tenova Group Website
Online Catalog
Gas Analyzers
O
2
Analyzers
CO Analyzers
CO
2
Analyzers
H
2
Analyzers
CH
4
Analyzers
NO
x
Analyzers
NO
2
Analyzers
SO
2
Analyzers
LEL Analyzers
Dew point Monitors
HC's Analyzers
H
2
S Analyzers
NH
3
Analyzers
He Analyzers
SF
6
Analyzers
Multigas
Applications
Flue Gas Analyzers
Emissions Analyzers
Process Gas Analyzers
Landfill Gas Analyzers
Biogas Analyzers
Handheld Landfill & Biogas
Heat Treating Analyzers
Syngas Production Analyzers
Steel-making Analyzers
Hydrogen Purity Analyzers
Ambient Air Monitors
Personnel Safety Monitors
Engine Exhaust Analyzers
Controlled Atmosphere Analyzers
Customer Service
Quick Question
FAQs
Spare Parts
Service Department
Application Questionnaire
Representatives
Site Map
Request Quote
Contact Us
Online Catalog
View Our Online Catalog.
Or search our online
catalog by entering in a
keyword or product
number in the box.
By Model
By Keyword
Applications
Flue Gas Analyzers.
Emissions Analyzers.
Process Gas Analyzers.
Landfill Gas Analyzers.
Biogas Analyzers.
Heat Treating Analyzers.
Syngas Production Analyzers.
Steel-Making Analyzers.
Hydrogen Purity Gas Analyzers.
Ambient Air Monitors.
Personnel Safety Monitors.
Engine Exhaust Analyzers.
Controlled Atmosphere Analyzers.
All Categories
>
By Primary Gas to be Measured
>
Oxygen Analyzers (O
2
)
>
Wall-mounted Oxygen in Ambient Air Monitor (O2)
>
Item # Model 501
Download PDF
Download PDF
Printable Page
Email This Page
Save To Favorites
Please wait…
Item # Model 501, Continuous Multigas Ambient Air Analyzer - 501 Series
larger image
The 501 Series four gas versions offer a choice of O2, CO2, CO, NO, & NO2. Single gas verions are also available with H2S, SO2, Cl2, & NH3. An O2 sensor may be added to the single gas versions to produce a toxic gas plus oxygen deficiency monitor.
A built-in pump draws in the sample for analysis. A ¼" plastic tube may be attached to the analyzer to sample a different area, such as a room or confined space. Standard system
comes with NEMA4 enclosure, built-in sampling pump, flow meter, and filter. Warm-up time is approximately four minutes after initial power-up. The operating ambient humidity range for
this series of analyzers is 0-90% RH non-condensing.
Alarm option - alarms may be provided for all gases. An optional audible 'Sonalert' will sound if any reading goes into alarm and display indication on front panel shows which gas is in alarm. Acknowledgement function will silence the audible 'Sonalert'.
Specifications
·
Applications
·
Features
·
Options
·
Calibration
Specifications
Method of Detection
O2, CO, SO2, NO, NO2, H2, CL2, NH3, and H2S by electrochemical sensor, % RH by dielectric ceramic sensor, CO2 by infrared sensor
Ranges Available
0-100 PPM NO
0-20 PPM Cl2
0-20 PPM H2S
0-20 PPM NH3
0-20 PPM NO2
0-200 PPM CO
0-200 PPM H2
0-25.0% O2
0-50 PPM SO2
0-5000 PPM CO2
-40°C to +40°C / 0-100% RH
Resolution
0.1% on O2; 1 PPM on PPM gases; 1% RH; 0.1°C Temp.
Accuracy & Repeatability
±2% of full scale
Drift
< 2% per month
Response Time (T-90)
Varies with individual sensor but generally under 2 minutes for full reading
Ambient Temperature Range
40° to 105°F (4° to 40°C)
ºC
Linearity
Better than ±2% of full scale
Size & Weight
NEMA 4: 51H x 41W x 26D cm (20"H x 16"W x 10"D)
Power
115 VAC, 60 Hz for recharging
220 VAC, 50 Hz
Output Options
4-20 mA into 500 ohms non-isolated standard
Isolated 4-20 mA
Alarms
Optional - One low or one high O2 alarm and one high alarm for all other gases. Separate SPDT relay contacts for each gas with 5A rating. Display indication. Common 'Sonalert' audible alarm with ACKN function.
Gases Measured
0) NH
3
- 0-20 PPM
1) O
2
- 0-25.0%
2) CO - 0-200 PPM
3) CO
2
- 0-5000 PPM
4) H
2
S - 0-20 PPM
5) SO
2
- 0-50 PPM
6) NO - 0-100 PPM
7) NO
2
- 0-20 PPM
8) Cl
2
- 0-20 PPM
Applications
For simultaneous monitoring of up to four gases in ambient air including O2, CO2, NO, NO2, CO, temperature, and % RH. Single gas versions are also available for H2S, SO2, Cl2, & NH3.
Features
All gas detectors contained in durable NEMA 4 wall-mounted enclosure
Separate sensor for each gas
Bright digital readout for gas readings
Built-in sampling pump
Easy to maintain modular layout
Options
Non-isolated 4-20mA recorder outputs
Isolated analog 4-20mA outputs available
Alarms with local indication and relay contacts with audible alarm & acknowledge
Red strobe light mounted on top of analyzer
Low Flow alarm with local indication and relay contact
Calibration
On clean air or nitrogen for Zero
On analyzed calibration gas for Span