Home
About Us
About NOVA
What's new at NOVA
About Tenova Goodfellow
About the Tenova Group
Tenova Group Website
Online Catalog
Gas Analyzers
O
2
Analyzers
CO Analyzers
CO
2
Analyzers
H
2
Analyzers
CH
4
Analyzers
NO
x
Analyzers
NO
2
Analyzers
SO
2
Analyzers
LEL Analyzers
Dew point Monitors
HC's Analyzers
H
2
S Analyzers
NH
3
Analyzers
He Analyzers
SF
6
Analyzers
Multigas
Applications
Flue Gas Analyzers
Emissions Analyzers
Process Gas Analyzers
Landfill Gas Analyzers
Biogas Analyzers
Handheld Landfill & Biogas
Heat Treating Analyzers
Syngas Production Analyzers
Steel-making Analyzers
Hydrogen Purity Analyzers
Ambient Air Monitors
Personnel Safety Monitors
Engine Exhaust Analyzers
Controlled Atmosphere Analyzers
Customer Service
Quick Question
FAQs
Spare Parts
Service Department
Application Questionnaire
Representatives
Site Map
Request Quote
Contact Us
Online Catalog
View Our Online Catalog.
Or search our online
catalog by entering in a
keyword or product
number in the box.
By Model
By Keyword
Applications
Flue Gas Analyzers.
Emissions Analyzers.
Process Gas Analyzers.
Landfill Gas Analyzers.
Biogas Analyzers.
Heat Treating Analyzers.
Syngas Production Analyzers.
Steel-Making Analyzers.
Hydrogen Purity Gas Analyzers.
Ambient Air Monitors.
Personnel Safety Monitors.
Engine Exhaust Analyzers.
Controlled Atmosphere Analyzers.
All Categories
>
By Primary Gas to be Measured
>
Oxygen Analyzers (O
2
)
>
Continuous Oxygen Analyzers for Hazardous Locations (O2)
>
Continuous Process Oxygen Gas Analyzer by Paramagnetic Sensor - 412 Series
>
Item # Model 412RMN7
Download PDF
Download PDF
Printable Page
Email This Page
Save To Favorites
Please wait…
Item # Model 412RMN7, Model 412RMN7 Paramagnetic Oxygen Analyzer, ex-proof sensor housing with rack mount control cabinet (two separate enclosures)
larger image
The Nova 412 Series O
2
analyzers utilize a magneto-dynamic paramagnetic measuring cell and powerful selenium cobalt magnet assembly with on-board pre-amplification to provide the highest standard of O
2
analysis. Accuracy is further augmented by built-in barometric pressure compensation and detector temperature control. For high purity applications (Model 412HP), a high resolution digital readout is added.
In operation, the magneto-dynamic cell makes use of the principle that oxygen is drawn into a magnetic field, thereby increasing the force exerted on a diamagnetic body suspended in the field. The amount of current necessary to restore the position of the body is directly proportional to the O2 level of the sample gas. Very few other gases respond this way, making this method of detection very specific to oxygen.
Cabinets
: Ex-proof sensor housing for
Class 1 Div 1 Grp BCD
areas, with rack mount control cabinet for non-hazardous areas (two separate enclosures)
Specifications
·
Applications
·
Features
·
Options
·
Calibration
·
Unique Applications
Specifications
Method of Detection
Magneto-dynamic paramagnetic O
2
cell
Ranges Available
With back-pressure control: 1.00, 2.00, 5.00, 25.00, 100.0 % O2
Without back-pressure control: 1.0, 2.0, 5.0 % O2
Resolution
0.1% or 0.01% O2, depending on back-pressure control
Accuracy & Repeatability
±1% of full scale
Drift
±0.2% of full scale per month
Response Time (T-90)
4 - 5 seconds at a sample flow of 1 LPM
Ambient Temperature Range
40 to 104°F (4 to 40°C)
Linearity
±0.5% of full scale or 0.05%, whichever is greater
Size & Weight
EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D)
RACK MOUNT: 22H x 48W x 47D cm (8.7"H x 19"W x 16"D)
Power
115 VAC, 60 Hz
220 VAC, 50 Hz
Output Options
4-20 mA into 500 ohms non-isolated standard
Alarms
High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating
Analyzer Type
O2 Analyzer
Hazardous Area Rating Options
Control Cabinet - General Purpose, Non-Hazardous
Detector Cabinet - NEMA7 Class 1 Division 1 Groups BCD
Applications
For continuous analysis of oxygen (O2) in process gas streams that contain gases that interfere with other methods of O2 measurement. For high accuracy or high purity applications.
Features
Highest accuracy O
2
analyzer, very stable
Fast response (T90 - 4 to 5 seconds) and bright digital readout
Linear over entire 0-100% range
Microprocessor control
Non-consumable O
2
detector, no periodic replacement required
Built in sample pump or pressure regulator, and 4-20mA output
Options
Hi/Low gas, low flow alarms available
Isolated analog, RS485 outputs available
High purity version available for 98-100% O
2
(412HP)
Calibration
Nitrogen for zero
Air or analyzed calibration gas for span