All Categories > By Primary Gas to be Measured > Hydrogen Chloride Analyzers (HCl) > Continuous Hydrogen Chloride (HCl) Alarm Monitors - 591 Series > Item # Model 591DR1  
Download PDF Download PDF     Printable Page     Email Email This Page     Save To Favorites Save To Favorites

Item # Model 591DR1, Hydrogen Chloride (HCl) Alarm Monitor, 1 remote sensor



Designed to monitor and alarm for Hydrogen Chloride (HCl) levels in ambient air near industrial sites, manufacturing facilities, combustion processes, etc. The HCl sensor is of the disposable electrochemical type with an expected life of between 3-4 years. The sensor needs no warm up time and is ready to go as soon as the monitor is turned on.

Model 591DR1 has one remote sensor which is electrically connected to the main cabinet.






Specifications  · Applications  · Features  · Options  · Unique Applications

Specifications

Method of Detection

Disposable electrochemical cell

Ranges Available

0-20 PPM standard

Resolution

1 PPM

Accuracy & Repeatability

±1% of full scale or 1 PPM, whichever is higher

Drift

Less than 1% of full scale or 2 PPM per week, whichever is greater

Response Time (T-90)

Less than 15 seconds to 90% step change

Ambient Temperature Range

32 to 120°F (0 to 40°C), may be operated at lower temperature with auxiliary heater

Linearity

±1% of full scale or 1 PPM, which ever is higher

Size & Weight

14" H x 12" W x 8" D (35.6 x 30.5 x 20.3 cm) @ 18 lbs. (8.2 kg)

Power

115 VAC, 60 Hz
220 VAC, 50 Hz

Output Options

0-1 VDC
4-20 mA

Alarms

Optional - Dual high HCl alarm light and relays (SPDT - 5A@ 230 VAC)
Optional: Audible alarm with 'Acknowledge' button


Applications
Designed to monitor and alarm for Hydrogen Chloride (HCl)levels in ambient air near industrial sites, manufacturing facilities, combustion processes, etc.



Features
  • Standard electrochemical cell
  • Fast response to the presence of NO2 in the air
  • Instant warm-up, no wait
  • Bright digital readout - no reading interpretation errors
  • Easy use and calibrate
  • Easy to maintain modular layout
  • 4-20mA output signal for recording
  • NEMA 12 fiberglass enclosure is standard




Options
  • 'Fail Safe' alarms available
  • Strobe light
  • NEMA 4 or 4X enclosures
  • Cold weather package for operation to -5°F (-20°C)




Unique Applications
    All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova. In many cases, we are able to build an analyzer specific to your needs.



 DOWNLOADS 

591 HCL
(PDF, 900KB)