All Categories > Multigas Analyzers > Item # 312 Series  
Download PDF Download PDF     Printable Page     Email Email This Page     Save To Favorites Save To Favorites

Item # 312 Series, Portable Flue Gas Analyzer for Oxides of Nitrogen



The Nova 312 Series Portable Flue Gas Analyzer for NOx utilizes a reliable, stable nitric oxide (NO) sensor which responds quickly to the NO present in flue gases or engine exhaust. NO is the major component (90-95%) of the NOx found in flue gases or engine exhaust (except diesel).

In operation, a built in sample pump draws in the gas sample through the S.S. probe, 12 ft sample hose, condensate removal filter, secondary filter and flowmeter then on to the NO sensor. The detected NO is displayed on a LCD digital meter which has a switchable backlight for use in dark areas.

The rechargeable battery provides enough power for about 20 hours of continuous operation and the analyzer can be used while it is being recharged. A red LED tells when to recharge and a green LED verifies that it is receiving recharging power. The recharger is included.





 Specifications   Applications   Features   Options   Calibration   

Method of Detection

Customer replaceable electrochemical NO sensor

Ranges Available

0-2000 PPM NOx (as NO)

Resolution

1 PPM NO

Accuracy & Repeatability

Better than 2% full scale

Drift

Within 1% full scale per 8 hours of continuous operation

Response Time (T-90)

20-30 seconds for 90% of step change

Ambient Temperature Range

12 to 49 ºC
55 to 120
ºF

Linearity

±2% of full scale

Size & Weight

K Style: 14"L x 10 1/2" W x 6" H @ 12 lbs ( 36 x 27 x 15 cm @ 5.5 kg)
WP Style: 11 1/2" L x 8" W x 7 1/4" H @ 8 lbs (29 x 20 x 18 cm @ 3.6 kg)

Power

AC/DC Operation, 115 VAC, 60 Hz for recharging (220 VAC 50Hz available)

Output Options

4-20 mA or 0-1 VDC

Alarms

NOx alarms with LED

Unique Applications

Note: For proper operation, the sample gas should also contain a small amount of oxygen.

All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova. In many cases, we are able to build an analyzer specific to your needs.

Primary Gas to be Measured

Oxides of Nitrogen (NOx)

Industry Type

Flue Gas or Emissions


 MORE IMAGES 

·  Application flue gas

·  Precooler


 DOWNLOADS 

312 Portable NO Flue Analyzer
(PDF, 741KB)