Item # 7200 Series, Continuous Flue Gas Analyzers



The Nova Model 7200 Series of flue gas analyzers are specifically designed for use on flue gases from combustion processes burning gaseous fuels.  The 7200 series analyzers can measure sample gases for oil or coal fired processes with the addition of a Model 7240 heated sample filter.  The 7200 can also measure flue gases in the presence of acidic or corrosive samples through the use of sample pre-conditioners.

Sample gas is drawn into the analyzer from the sampling probe heated filter or sample pre-conditioner, then pumped through a condensate removal system. Any condensate formed is collected then automatically purged.  Next, the dried sample gas is filtered again, then flows through a pressure regulator, PTFE liquid blocker, calibration gas valves, low flow switch, flow meter then on to the gas detectors.  An optional vacuum switch at the pump inlet warns if the pre-filter is becoming plugged up.

The 7200 Series analyzers are available in any combination of O2, CO, CO2, NOx (as NO or NO + NO2), SO2, or combustibles, with separate digital readouts and outputs for each.  Special sampling probes are available for high temperature applications up to 3200°F (1760°C).  The 7200 Series is multi-sample point capable (consult Nova).





 Specifications   Applications   Features   Options   

Method of Detection

% O2 by zirconia sensor when applicable
% O2, 10-1000 PPM NO, NO2 CO and SO2 by electrochemical sensor

CO2 >1000 PPM, % CO and SO2 by infrared detector

Combustibles by catalytic combustibles detector with air 'make-up' system

High accuracy % O2 by paramagnetic sensor

Ranges Available

0-100 PPM to 0-5% SO2
0-100 to 0-100% CO

0-100 to 0-5000 PPM NO

0-100 to 0-800 PPM NO2

0-2, 0-5, 0-10% Combustibles

0-20% CO2

0-5 to 0-25% O2

Resolution

0.1% on %, 1 PPM on PPM

Accuracy & Repeatability

±1-2% of full scale - depending on gas measured and range

Drift

Less than 2% of full scale per month

Response Time (T-90)

20-30 seconds to 90% of step change

Ambient Temperature Range

32 to 122°F (0 to 50°C) @ 5-95% RH non-condensing. Lower temperatures (-5°F, -20°C) with Cold Weather Package. ºC

Linearity

±1% of full scale

Size & Weight

Dimensions and weight will vary with configurations selected

Power

115 VAC, 60 Hz
220 VAC, 50 Hz

Output Options

OP1 - 4-20 mA non-isolated
OP2 - 4-20 mA isolated

OP3 - 0-5 V

OP4 - 0-10 V

OP5 - RS-485

OP6 - Modbus

Alarms

High or low alarm contacts available for all gases and low flow

Unique Applications

    All Nova analyzers are built using proven technologies and techniques.

Primary Gas to be Measured

Oxygen (O2)

Code Numbers for Gases Measured

O2 by electrochemical sensor

Sampling System

Std SS probe with unheated pre-filter (Std. probe 3/8" O.D. x 18") (9.5 x 460 mm)

Sample Points

1 Sample point (no sequencing)

Display Type

D1 - LED display (s) - Manual potentiometer calibration
D2 - LED display (s) - Manual push-button calibration

D3 - Microprocessor controller with single graphic display. Allows auto sequencing, RS-485 output, 'CAL NOW' and one-step

D4 - Same as D3 but with full auto-calibration

Industry Type

Flue Gas or Emissions