New Call-to-action
The Nova 320 Series of Portable Flue Gas Oxygen Analyzers utilize a reliable, stable oxygen sensor which responds quickly to the oxygen present in a flue gas sample. Its life expectancy is between 3 and 4 years. The sensor is very easy for the customer to replace and at a reasonable cost.

A rechargeable battery provides enough power for the pump and electronics for about 8 hours of operation. The analyzer can still be operated while it is being charged. The analyzer is supplied with recharger and a 12ft (4m) sample hose and a stainless steel probe.

The Model 320 can optionally indicate stack temperature (Model 320T; 0-1800°F or 0-1000°C) for doing fuel efficiency calculations. The temperature sensor is built into the sampling probe. Efficiency charts for each fuel are provided.
Unit of Measure

Specifications

Method of Detection

N/A Long life electrochemical oxygen sensor

Ranges Available

N/A 0-5.0%, 0-10.0%, 0-25.0%, 0-50.0%

Resolution

N/A 0.1% O2

Accuracy & Repeatability

N/A ±1% of full scale (±2% of full scale above 30% O2)

Drift

N/A < 2% of full scale for 8 hours of operation

Response Time (T-90)

N/A 8-10 seconds for 90% of step change

Ambient Temperature Range

N/A 0 to 40 ºC32 to 105 ºF

Linearity

N/A ±1% of full scale

Size & Weight

N/A approx. 26 x 18 x 13 cm @ 3.4 kg (10" x 7" x 5" @ 7.5lbs)

Power

N/A 12V battery operation. 115VAC 60Hz for recharging (220VAC 50Hz available)

Output Options

N/A 4-20mA

Hazardous Area Rating Options

N/A General Purpose, Non-Hazardous

Applications

N/A

        Analysis of oxygen (O
2
      ) in flue gases from any type of fuel. For checking combustion efficiency, air infiltration and burner & control performance of furnaces, heaters and boilers. May be used in commercial, industrial and residential settings.

Features

N/A

  • Rugged design that is easy to operate and maintain
  • Fast warm-up and response
  • Long-life electrochemical oxygen sensor (3-4 year life)
  • Digital readout meter
  • Rechargeable battery operation
  • Built in sample pump, filter and flow meter
  • Continuous condensate removal
  • For use on any fuel
  • Suitcase cabinet (K) weatherproof when closed
  • Stainless steel probe with sample hose
  • Pays for itself in months through fuel savings

Options

N/A

  • Output - 4-20mA
  • Special sampling probes
  • Sample pre-cooler
  • Suitcase (K) style cabinet available
  • On-board data-logging to USB stick

Calibration

N/A

  • On air for span
  • On nitrogen for zero

Unique Applications

N/A

    All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova. In many cases, we are able to build an analyzer specific to your needs.

View Our
Product Catalog
Have a question?
Contact Us
Ready to get started?
Request Quote