Continuous Process PPM Level Carbon Monoxide Gas Analyzer - 480 Series
Continuous Carbon Monoxide Analyzers (Continuous CO Analyzers)
Process PPM Level Carbon Monoxide analyzer from the Nova FLEXI-NOVA Series Platform, designed for light-duty continuous gas measurements.
Unit of Measure
Items |
/Asset/flexinovaN42.jpg Model 480N4 Model 480N4 PPM Carbon Monoxide Analyzer, Wall Mounted NEMA4 (IP65) Enclosure Rating |
/Asset/N4N7-21.jpg Model 480N4N7 Model 480N4N7, Carbon Monoxide Analyzer, ex-proof sensor housing with NEMA4 wall-mount control cabinet (two separate enclosures) |
/Asset/N7MC-generic.jpg Model 480N7MC Model 480N7MC, Carbon Monoxide Analyzer, Wall Mounted NEMA7 UL/CSA Ex-proof with Non-intrusive Magnetic Calibration, Class 1 Div 1 Group BCD |
/Asset/RMN7-21.jpg Model 480RMN7 Model 480RMN7, Carbon Monoxide Analyzer, ex-proof sensor housing with rack mount control cabinet (two separate enclosures) |
/Asset/N4-+-D1-&-D2-purge21.jpg Model 480 D1 or D2 Model 480 D1 or D2, Carbon Monoxide Analyzer - 480 Series; NEMA 4 cabinet with Hazardous Area Purge System |
|||||
Method of Detection | N/A Customer replaceable electrochemical 'fuel cell' CO sensor | N/A Customer replaceable electrochemical 'fuel cell' CO sensor. Expected life 1 to 3 years depending on typical measurement concentrations. | N/A Customer replaceable electrochemical 'fuel cell' CO sensor. Expected life 1 to 3 years depending on typical measurement concentrations. | N/A Customer replaceable electrochemical 'fuel cell' CO sensor. Expected life 1 to 3 years depending on typical measurement concentrations. | N/A Customer replaceable electrochemical 'fuel cell' CO sensor. Expected life 1 to 3 years depending on typical measurement concentrations. | |||||
Ranges Available | N/A Any range from 0-100 PPM to 0-10000 PPM C0 | |||||||||
Accuracy & Repeatability | N/A ±1% of full scale based on 0-2,000 PPM range | N/A ±1% of full scale based on 0-2,000 PPM range | N/A ±1% of full scale based on 0-2,000 PPM range | N/A ±1% of full scale based on 0-2,000 PPM range | N/A ±1% of full scale | |||||
Drift | N/A Less than 1% of full scale per month or 10 PPM, whichever is greater | N/A Less than 1% of full scale per month or 10 PPM, whichever is greater | N/A Less than 1% of full scale per month or 10 PPM, whichever is greater | N/A Less than 1% of full scale per month or 10 PPM, whichever is greater | N/A Less than 1% of full scale per month | |||||
Response Time (T-90) | N/A Usually 6-8 seconds to 90% step change | N/A 6-8 seconds to 90% step change | N/A 6-8 seconds to 90% step change | N/A 6-8 seconds to 90% step change | N/A 6-8 seconds to 90% step change | |||||
Ambient Temperature Range | N/A 40 to 104°F (4 to 40°C). Optional: up to 130°F (55°C) with cabinet cooler | N/A 40 to 104°F (4 to 40°C) | N/A 40 to 104°F (4 to 40°C) | N/A 40 to 104°F (4 to 40°C) | N/A 40 to 104°F (4 to 40°C). Optional: up to 130°F (55°C) with cabinet cooler | |||||
Linearity | N/A Usually ±1.5% of full scale, depending on range and application | |||||||||
Size & Weight | N/A NEMA 4: 51H x 41W x 26D cm (20"H x 16"W x 10"D) | N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) NEMA 4: 51H x 41W x 26D cm (20"H x 16"W x 10"D) | N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) | N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) RACK MOUNT: 22H x 48W x 47D cm (8.7"H x 19"W x 16"D) | N/A NEMA 4: 61H x 51W x 31D cm (24"H x 20"W x 12"D) (not including purge panel & vent) | |||||
Power | N/A 115 VAC, 60 Hz 220 VAC, 50 Hz | |||||||||
Alarms | N/A High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating Low flow alarm | |||||||||
Options | N/A Cabinet coolers can be fitted to most models Isolated analog, RS232, RS485, serial outputs available Light duty sample conditioning systems available for removal of moisture and/or dust | N/A Hi/Low gas, Low Flow, and diagnostic alarms available Isolated 4-20 mA, RS232, RS485 serial outputs | N/A Hi/Low gas, Low Flow alarms available Isolated 4-20mA, RS232, RS485, serial outputs | N/A Hi/Low gas, Low Flow alarms available Isolated 4-20 mA, RS232, RS485, serial outputs | N/A Cabinet coolers can be fitted to most models Cabinet purge system available for use in hazardous areas Hi/Low gas, Low Flow alarms available High temperature filters and probes Isolated 4-20mA, RS232, RS485, serial outputs Light duty sample conditioning systems available for removal of moisture and/or dust | |||||
Analyzer Type | N/A CO Analyzer (ppm) | |||||||||
Hazardous Area Rating Options | N/A General Purpose, Non-Hazardous | N/A Control Cabinet - General Purpose, Non-Hazardous Detector Cabinet - NEMA7 Class 1 Division 1 Groups BCD | N/A Class 1, Div 1, Grp A-D Hazardous Area Rating | N/A Control Cabinet - General Purpose, Non-Hazardous Detector Cabinet - NEMA7 Class 1 Division 1 Groups BCD | N/A Class 1 Div 2 or Class 1 Div 1 Hazardous Area Ratings available | |||||
|