The Nova FLEXI-NOVA Series Platform has been designed for continuous gas measurements in applications and environments that are less intensive. Lab work, research, clean processes, pre-treated / pre-cleaned produced gases, and others, may benefit from the FLEXI-NOVA series.
For clean process measurements of ppm-level CO gas using an electro-chemical sensor. All sensors / detectors are temperature-controlled or temperature-compensated for maximum analytical stability. Easy calibration using touch-screen controls. Serial Output Package allows connection & data-logging to personal computers via a choice of USB / RS-232 / RS-485.
Cabinets: Wall Mounted NEMA7 UL/CSA Class1 Div1 Explosion-proof sensor cabinet with 19" rack mount control cabinet (two separate cabinets)
For clean process measurements of ppm-level CO gas using an electro-chemical sensor. All sensors / detectors are temperature-controlled or temperature-compensated for maximum analytical stability. Easy calibration using touch-screen controls. Serial Output Package allows connection & data-logging to personal computers via a choice of USB / RS-232 / RS-485.
Cabinets: Wall Mounted NEMA7 UL/CSA Class1 Div1 Explosion-proof sensor cabinet with 19" rack mount control cabinet (two separate cabinets)
Unit of Measure
Specifications
Method of Detection |
N/A Customer replaceable electrochemical 'fuel cell' CO sensor. Expected life 1 to 3 years depending on typical measurement concentrations. |
Ranges Available |
N/A Any range from 0-100 PPM to 0-10000 PPM C0 |
Resolution |
N/A 1 PPM CO up to 2,000 PPM; 10 PPM for greater than 2,000 PPM |
Accuracy & Repeatability |
N/A ±1% of full scale based on 0-2,000 PPM range |
Drift |
N/A Less than 1% of full scale per month or 10 PPM, whichever is greater |
Response Time (T-90) |
N/A 6-8 seconds to 90% step change |
Ambient Temperature Range |
N/A 40 to 104°F (4 to 40°C) |
Linearity |
N/A Usually ±1.5% of full scale, depending on range and application |
Size & Weight |
N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) RACK MOUNT: 22H x 48W x 47D cm (8.7"H x 19"W x 16"D) |
Power |
N/A 115 VAC, 60 Hz 220 VAC, 50 Hz |
Output Options |
N/A 4-20 mA into 500 ohms non-isolated standard Isolated 4-20 mA, RS232, RS485, serial outputs |
Alarms |
N/A High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating Low flow alarm |
Analyzer Type |
N/A CO Analyzer (ppm) |
Hazardous Area Rating Options |
N/A Control Cabinet - General Purpose, Non-Hazardous Detector Cabinet - NEMA7 Class 1 Division 1 Groups BCD |
Applications
N/A For continuous analysis of up to 0-10,000 PPM carbon monoxide (CO) in process gas streams using an electrochemical detector. |