For continuous analysis of Oxygen (O2) in process gas streams that contain gases that interfere with other methods of O2 measurement. For high accuracy or high purity applications.
Item # |
Enclosure and Mounting Details |
Resolution |
Response Time (T-90) |
Power |
Analyzer Type |
Hazardous Area Rating Options |
---|---|---|---|---|---|---|
Model 412N4 | N/A Process Analyzer for Oxygen by Paramagnetic Sensor, Wall Mounted NEMA4 (IP65) Enclosure Rating | Resolution N/A 412 - 0.1% O2; 412HP - 0.01% O2 | Response Time (T-90) N/A 4-5 seconds | Power N/A 115 VAC, 60 Hz 220 VAC, 50 Hz | Analyzer Type N/A O2 Analyzer | Hazardous Area Rating Options N/A General Purpose, Non-Hazardous |
Model 412N4X | N/A Process Analyzer for Oxygen by Paramagnetic Sensor, Wall Mounted Corrosion-resistant NEMA4X (IP65) Enclosure Rating | Resolution N/A 412 - 0.1% O2; 412HP - 0.01% O2 | Response Time (T-90) N/A 4-5 seconds | Power N/A 115 VAC, 60 Hz 220 VAC, 50 Hz | Analyzer Type N/A O2 Analyzer | Hazardous Area Rating Options N/A General Purpose, Non-Hazardous |
Model 412RM | N/A Process Analyzer for Oxygen by Paramagnetic Sensor, 19" (483mm) Rack Mounted, on Sliding Rails | Resolution N/A 412 - 0.1% O2; 412HP - 0.01% O2 | Response Time (T-90) N/A 4-5 seconds | Power N/A 115 VAC, 60 Hz 220 VAC, 50 Hz | Analyzer Type N/A O2 Analyzer | Hazardous Area Rating Options N/A General Purpose, Non-Hazardous |
Model 412N7MC | N/A Process Analyzer for Oxygen by Paramagnetic Sensor, Wall Mounted NEMA7 UL/CSA Explosion-proof with Non-intrusive Magnetic Calibration, Class 1 Div 1 Group BCD | Resolution N/A 412 - 0.1% O2; 412HP - 0.01% O2 | Response Time (T-90) N/A 4-5 seconds | Power N/A 115 VAC, 60 Hz 220 VAC, 50 Hz | Analyzer Type N/A O2 Analyzer | Hazardous Area Rating Options N/A Class 1, Div 1, Grp A-D Hazardous Area Rating |
Model 412RMN7 | N/A Process Analyzer for Oxygen by Paramagnetic Sensor, ex-proof sensor housing with rack mount control cabinet (two separate enclosures) | Resolution N/A 412 - 0.1% O2; 412HP - 0.01% O2 | Response Time (T-90) N/A 4-5 seconds | Power N/A 115 VAC, 60 Hz 220 VAC, 50 Hz | Analyzer Type N/A O2 Analyzer | Hazardous Area Rating Options N/A Class 1, Div 1, Grp A-D Hazardous Area Rating |
Model 412D2 | N/A Process Analyzer for Oxygen by Paramagnetic Sensor, Wall Mounted NEMA4 (IP65) Enclosure Rating with haz area cabinet purge system | Resolution N/A 412 - 0.1% O2; 412HP - 0.01% O2 | Response Time (T-90) N/A 4-5 seconds | Power N/A 115 VAC, 60 Hz 220 VAC, 50 Hz | Analyzer Type N/A O2 Analyzer | Hazardous Area Rating Options N/A Class 1, Div 2 Hazardous Area Rating |