For continuous analysis of trace PPM levels of Oxygen (O2) in process gas streams. Applications include blanketing mixtures, glove boxes, electronics, research, Hydrogen/Nitrogen mixtures, and many others.
Item # |
Enclosure and Mounting Details |
Resolution |
Response Time (T-90) |
Power |
Analyzer Type |
Hazardous Area Rating Options |
---|---|---|---|---|---|---|
Model 415N4 | N/A Process Analyzer for Trace Oxygen by Electrochemical Sensor, Wall Mounted NEMA4 (IP65) Enclosure Rating | N/A ±1 PPM | N/A O2 sensor may require an initial purge down from air to low PPM O2 which may last up to 6 hours. After purge, T90 response from 1000 to 0 PPM O2 is 30 seconds. | N/A 115 VAC, 60 Hz 220 VAC, 50 Hz | N/A O2 Analyzer | N/A General Purpose, Non-Hazardous |
Model 415N4X | N/A Process Analyzer for Trace Oxygen by Electrochemical Sensor, Wall Mounted Corrosion-resistant NEMA4X (IP65) Enclosure Rating | N/A ±1 PPM | N/A O2 sensor may require an initial purge down from air to low PPM O2 which may last up to 6 hours. After purge, T90 response from 1000 to 0 PPM O2 is 30 seconds. | N/A 115 VAC, 60 Hz 220 VAC, 50 Hz | N/A O2 Analyzer | N/A General Purpose, Non-Hazardous |
Model 415RM | N/A Process Analyzer for Trace Oxygen by Electrochemical Sensor, 19" (483mm) Rack Mounted, on Sliding Rails | N/A ±1 PPM | N/A O2 sensor may require an initial purge down from air to low PPM O2 which may last up to 6 hours. After purge, T90 response from 1000 to 0 PPM O2 is 30 seconds. | N/A 115 VAC, 60 Hz 220 VAC, 50 Hz | N/A O2 Analyzer | N/A General Purpose, Non-Hazardous |
Model 415N7MC | N/A Process Analyzer for Trace Oxygen by Electrochemical Sensor, Wall Mounted NEMA7 UL/CSA Explosion-proof with Non-intrusive Magnetic Calibration, Class 1 Div 1 Group BCD | N/A ±1 PPM | N/A O2 sensor may require an initial purge down from air to low PPM O2 which may last up to 6 hours. After purge, T90 response from 1000 to 0 PPM O2 is 30 seconds. | N/A 115 VAC, 60 Hz 220 VAC, 50 Hz | N/A O2 Analyzer | N/A Class 1, Div 1, Grp A-D Hazardous Area Rating |
Model 415RMN7 | N/A Process Analyzer for Trace Oxygen by Electrochemical Sensor, ex-proof sensor housing with rack mount control cabinet (two separate enclosures) | N/A ±1 PPM | N/A O2 sensor may require an initial purge down from air to low PPM O2 which may last up to 6 hours. After purge, T90 response from 1000 to 0 PPM O2 is 30 seconds. | N/A 115 VAC, 60 Hz 220 VAC, 50 Hz | N/A O2 Analyzer | N/A Class 1, Div 1, Grp A-D Hazardous Area Rating |
Model 415D2 | N/A Model 415 with NEMA 4 cabinet with Hazardous Area Purge System; available for Class 1 Div1 & Div2 hazardous areas | N/A ±1 PPM | N/A O2 sensor may require an initial purge down from air to low PPM O2 which may last up to 6 hours. After purge, T90 response from 1000 to 0 PPM O2 is 30 seconds. | N/A 115 VAC, 60 Hz 220 VAC, 50 Hz | N/A O2 Analyzer | N/A Class 1, Div 2 Hazardous Area Rating |