All Categories > Multigas Analyzers > View Items  
Download PDF Download PDF     Printable Page     Email Email This Page     Save To Favorites Save To Favorites

Multigas Analyzers

Check up to five results to perform an action.



Use "Search Items" button to combine all gases to be measured by one instrument.

Use "Compare Items" button to compare methods of detection.


Search Items


Compare Items
   
  Results 1 - 25 of 27 1 2 

Item #

Analyzer

Method of Detection

Resolution

Alarms

Applications

Sort by
402 Series Automatic Sequencer No detection; sequences sample streams to (separately sold) analyzer for detection N/A N/A
    Allows a single Nova gas analyzer to be time shared over many sample points. It can be controlled locally or remotely. Applications include multiple greenhouses, mushroom farms, multiple flue gas ducts, multiple landfill well or area sampling.
309 Series Portable Analyzer for Carbon Dioxide & Oxygen Electrochemical O2 sensor
Infrared detector for CO2
0.1% O2 and CO2 N/A
    Analysis of Carbon Dioxide (CO2) and Oxygen (O2). For checking combustion efficiency, burner & control performance of furnaces, heaters and boilers in commercial, industrial and residential applications.
5000 Series Portable Flue Gas Analyzer for Any Combination of O2, CO, CO2, NOx, SO2and Stack Temperature Customer replaceable electrochemical O2, CO, SO2, and NO sensors
Solid state infrared detector for CO2
±0.1% CO2, 1 PPM, 1°F (1°C) N/A
    Analysis of carbon Monoxide (CO), carbon dioxide (CO2), sulfur dioxide (SO2), and oxide of nitrogen (NOx) emissions. For checking combustion efficiency, burner & control performance, and detection of air infiltration on furnaces, heaters and boilers. May be used in commercial, industrial and residential settings.
312 Series Portable Flue Gas Analyzer for Oxides of Nitrogen Customer replaceable electrochemical NO sensor 1 PPM NO NOx alarms with LED
    Analysis of oxides of nitrogen (NOx) as nitric oxide (NO) for boiler, furnace, or engine exhaust.
313 Series Portable Flue Gas Analyzer for Oxides of Nitrogen Customer replaceable electrochemical nitric oxide and nitrogen dioxide sensors Expected life 2-3 year each 1 PPM on 0-2000 PPM; 10 PPM on higher ranges NO, NO2 or NOx alarms with LED
    Analysis of oxides of nitrogen (NOx) such as nitric oxide (NO) and/or nitrogen dioxide (NO2). For boiler, furnace, or engine exhaust monitoring and analysis.
360 Series Portable Flue Gas Analyzer for Oxygen and Carbon Monoxide Customer replaceable electrochemical O2 and CO sensors 0.1% O2, 1 PPM CO High CO alarm with LED
    Analysis of oxygen (O2) and carbon monoxide (CO). For checking combustion efficiency, air infiltration, and burner & control performance of furnaces, heaters and, boilers. May be used in commercial, industrial and residential settings.
350 Series Portable Flue Gas Analyzer for Oxygen & Combustibles Catalytic oxidation detector for combustibles. Expected life is 2-3 years for each
Customer replaceable electrochemical O2 sensor
0.1% O2 and combustibles N/A
    Analysis of oxygen (O2) and combustibles. For checking the combustion efficiency, and burner & control performance of furnaces, heaters, and boilers. May be used in commercial, industrial, and residential settings.
352 Series Portable Flue Gas Analyzer for Oxygen, Carbon Monoxide and Combustibles Catalytic oxidation detector for combustibles; expected life is 3-4 years for each
Customer replaceable electrochemical O2 and CO sensors
0.1% O2, CO and combustibles N/A
    Analysis of oxygen (O2), carbon dioxide (CO) and combustibles. For checking the combustion efficiency, and burner & control performance of furnaces, heaters, and boilers. May be used in commercial, industrial, and residential settings.
375 Series Portable Flue Gas Analyzer for Oxygen, Carbon Monoxide and Carbon Dioxide Customer replaceable electrochemical oxygen and CO sensors
Solid state infra-red detector for CO2
0.1% O2, 1 PPM on CO and CO2 N/A
    Analysis of oxygen (O2), carbon monoxide (CO), and carbon dioxide (CO2). For checking the combustion efficiency and burner & control performance of furnaces, heaters, and boilers. May be used in commercial, industrial, and residential settings.
362 Series Portable Flue Gas Analyzer for Oxygen, Carbon Monoxide and Oxides of Nitrogen Customer replaceable electrochemical O2, CO and NO sensor 0.1% O2; 1 PPM on CO and NOx N/A
    Analysis of oxygen (O2), carbon monoxide (CO), and oxides of nitrogen (NOx as NO). For checking combustion efficiency, air infiltration, NOx emissions, and burner & control performance of furnaces, heaters, and boilers. May be used in commercial, industrial and residential applications.
376 Series Portable Flue Gas Analyzer for Oxygen, Carbon Monoxide, Carbon Dioxide and Oxides of Nitrogen Customer replaceable electrochemical O2, CO and NO sensors
Solid state infra-red detector for CO2
N/A N/A
    Analysis of oxygen (O2), carbon monoxide (CO), carbon dioxide (CO2) and oxides of nitrogen (NOx as NO). For checking the combustion efficiency and burner & control performance of furnaces, heaters, and boilers. May be used in commercial, industrial, and residential settings.
7200 Series Continuous Flue Gas Analyzers % O2 by zirconia sensor when applicable
% O2, 10-1000 PPM NO, NO2 CO and SO2 by electrochemical sensor

CO2 >1000 PPM, % CO and SO2 by infrared detector

Combustibles by catalytic combustibles detector with air 'make-up' system

High accuracy % O2 by paramagnetic sensor
0.1% on %, 1 PPM on PPM High or low alarm contacts available for all gases and low flow
    Continuous analysis of flue gas for any combination and range of O2, CO, CO2, SO2, NOx (NO or NO + NO2) or combustibles from combustion processes.
3255 Series Portable Analyzer for PPM Oxygen and Dew Point Customer replaceable O2 sensor, AlO2 Dew Point Sensor, T/C Cell for H2 ±1PPM O2, ±1°C or °F Dew Point, 0.1% H2 Optional
    Designed for use on low oxygen (O2) and low dew point (DP) process gases
309A Series Portable Analyzer for Carbon Dioxide & Oxygen in Agricultural Applications Electrochemical O2 sensor
Infrared detector for CO2
0.1% on % versions or 10 PPM on PPM versions N/A
    For checking carbon dioxide (CO2) and oxygen (O2) in controlled atmosphere (C/A) storage rooms, welding gas mixtures, and other process applications.
7460 Series Rugged Portable Analyzers for Engine Exhaust Emissions CO (low-range), NO, NO2 and O2 by long life electrochemical sensor.
CO (standard range), CO2, and HC by infrared detector
0.1% on % gas, 1 PPM on PPM gas N/A
    For checking engine exhaust emissions for diesel, gasoline, propane, or natural gas powered 2 and 4 cycle engines. Analysis of Carbon Monoxide (CO), Hydrocarbons (HC’s), Carbon dioxide (CO2), Oxygen (O2), Oxides of Nitrogen (NOx), Nitric Oxide (NO), and Nitrogen dioxide (NO2).
380 Series Portable Tri Gas Analyzer for Hydrogen Purging Temperature compensated thermal conductivity (T/C) cell 0.1% of gas measured N/A
    For checking purity of hydrogen (H2) in H2-cooled generators and synchronous converters. The Model 380 Series will also monitor the safe purging of H2 during shut down.
382 Series Portable Tri Gas Analyzer for Hydrogen Purging with separate O2 channel Thermal-conductivity (T/C) cell for H2; Electrochemical sensor for O2 0.1% of gas measured N/A
    For checking purity of hydrogen (H2) in H2-cooled generators and synchronous converters. The Model 380 Series will also monitor the safe purging of H2 during shut down.
436 Series Tri-Gas Analyzer to Monitor Purity and Purging of Hydrogen Cooled Power Generator Temperature controlled thermal conductivity (T/C) cell, cannot be burned out due to loss of flow or changing gases ±0.1% of gas measured Alarm set points are field adjustable
Alarms have front panel light for each alarm and SPST (normally energized) relay with 5A rating at 250VAC non-inductive load

Dual alarms are provided for low H2 purity. Detector fail alarm also provided as standard
    For continuous analysis of hydrogen (H2) purity and for purge monitoring of hydrogen-cooled generators and synchronous converters.
425 Series Continuous Process Analyzer for Binary Gas Mixtures by Thermal Conductivity CH4 in N2, air, or CO2; SF6 in CO2, etc.
CO2 in N2, H2, air, Ar, O2, He, etc

O2 in Ar, CO2, He, H2, etc

RTD-based TC cell can be used to measure almost any binary gas mixture such as H2 in N2, O2, air, SO2, Ar, He, NH3, etc
0.1% of gas to be measured High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating
Low flow alarm
    For continuous analysis of many binary gas mixtures comprised of H2, CO2, O2, CH4, SO2, Ar, He, NH3, SF6, air, and others. Applications include heat treating atmospheres, welding gas mixtures, blanketing gas mixtures, ammonia synthesis, leak detection, purge monitoring, flue gas, magnesium blanketing by SF6 and others.
920 Series Continuous Analyzers for Landfill Site and Biogas Recovery & Processing Electrochemical sensor for O2 & H2S, infrared detector for CH4 & CO2 0.1% on CO2, O2, & CH4, 1 PPM on H2S High O2, high CO2, low CH4, low flow; SPDT relays with 10A contacts
    For continuous analysis of oxygen (O2), methane (CH4), and/or carbon dioxide (CO2) in recovered gases from landfill and biogas sites. Hydrogen sulfide (H2S) readout optional.
910 Series Continuous Analyzers for Landfill Site and Biogas Recovery & Processing Electrochemical sensor for O2 , infrared detector for CH4 & CO2 0.1% on CO2, O2, & CH4 High O2, high CO2, low CH4, low flow; SPDT relays with 10A contacts
    For continuous analysis of oxygen (O2), methane (CH4), and/or carbon dioxide (CO2) in recovered gases from landfill sites. Hydrogen sulfide (H2S) readout optional.
7900 Series Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems Dielectric ceramic sensor for Dew Point
Electrochemical sensor for O2

NDIR infrared detector for CO, CO2, CH4 & NH3

Thermal conductivity cell for H2
0.1%, 1 PPM, 1°F (Dew Point) High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating
Low flow alarm
    For continuous monitoring of any combination of heat treat atmosphere gases such as Oxygen (O2), Methane (CH4), Carbon Dioxide (CO2), Carbon Monoxide (CO), Hydrogen (H2), Ammonia (NH3), and Dew Point (standard and low ranges). Also available for other industrial process gases.
7900P Series Portable Gas Analyzer for Heat Treating and Other Hydrogen-Based Industrial Processes Customer may select one or more combinations of CO, CO2, H2, CH2, O2, or dew point 0.1% on % versions, 10 PPM on PPM versions N/A
    For monitoring heat treating atmosphere gases in any combination of carbon monoxide (CO), carbon dioxide (CO2), methane (CH4), hydrogen (H2), oxygen (O2) and dew point. Also available for other industrial processes that include hydrogen.
501 Series Continuous Multi-Gas Ambient Air Analyzer O2, CO, SO2, NO, NO2, H2, CL2, NH3 and H2S by electrochemical sensor, % RH by dielectric ceramic sensor, CO2 by infrared sensor 0.1% on % gas, 1 PPM on PPM gas One low O2 alarm and one high alarm for all other gases. Separate relay contacts for each gas with 5A rating. Separate indicator lights. Common 'Sonalert' audible alarm with reset button. Field-adjustable set points.
    For simultaneous analysis and alarm of up to four of any combination of O2 deficiency, CO2, SO2, NO, NO2, H2, CO, CL2, NH3, H2S, % RH, and temperature of ambient air.
340 Series Portable Analyzer for Oxygen and Hydrogen Long-life electrochemical O2 sensor, temperature-compensated thermal conductivity (T/C) H2 cell cannot be burned out due to loss of flow or changing gases 0.1% on % ranges; 1 PPM on PPM O2 range O2 and H2 alarms with LED (optional) Analysis of oxygen/hydrogen (O2/H2) in exothermic furnace atmospheres for copper, brass or steel anealing, neutral heating, sintering, glass metal beds or oxide coating of steel.