Gases Measured |
N/A O2, CO, CO2, SO2, NO, NO2 |
Method of Detection |
N/A % O2, 10-1000 PPM NO, NO2, CO, & SO2 by electrochemical sensor CO2, >1000 PPM & % CO & SO2 by infrared detector Combustibles by catalytic detector |
Ranges Available |
N/A 0-100 PPM to 0-100 % CO 0-100 PPM to 0-5% SO2 0-100 to 0-2,000 PPM NO 0-100 to 0-800 PPM NO2 0-2, 0-5, 0-10% Combustibles 0-20% CO2 0-25% O2 |
Resolution |
N/A 0.1 % on % ranges, 1 PPM on PPM ranges |
Accuracy & Repeatability |
N/A ±1-2% of full scale - depending on gas measured and ranges |
Drift |
N/A Less than 2% of full scale per month |
Response Time (T-90) |
N/A usually 20-30 seconds to 90% of step change |
Ambient Temperature Range |
N/A 32-122°F (0-50°C) @ 5-95% RH non-condensing. Lower temperatures (-5°F, -20°C) with Cold Weather Package. |
Linearity |
N/A usually ±1% of full scale |
Size & Weight |
N/A 762 H x 610 W x 305 D mm (30” H x 24” W x 12” D) Dimensions and weight will vary with configurations selected |
Power |
N/A 115 VAC, 60 Hz 220 VAC, 50 Hz |
Alarms |
N/A High or low alarm contacts available for all gases and low flow |
Sampling System |
N/A Model 7240 heated pre-filter with SS Probe and manual blow back |
Display Type |
N/A Touchscreen display of gas readings |
Output Options |
N/A Isolated 4-20 mA standard RS232, RS485, MODBUS®, Ethernet outputs optional |
Analyzer Type |
N/A Continuous Flue Gas Analyzer |
Industry Type |
N/A Flue Gas or Emissions |
N/A Continuous analysis of flue gas for any combination and range of O2, CO, CO2, SO2, NOx (as NO or NO + NO2) or combustibles from combustion processes. |
N/A
|