Method of Detection |
N/A Electrochemical CO sensor |
Ranges Available |
N/A 0-200 PPM standard on all models, except 580BA which has a 0-50 PPM sensor |
Resolution |
N/A 1 PPM CO |
Accuracy & Repeatability |
N/A Better than 1% of full scale |
Drift |
N/A Less than 1% of full scale per week |
Response Time (T-90) |
N/A Less than 15 seconds to 90% step change |
Ambient Temperature Range |
N/A 40° to 104°F (5° to 40°C) |
Linearity |
N/A ± 1% of full scale |
Size & Weight |
N/A 20" H x 16" W x 10" D @ 20lbs. (51 x 41 x 26 cm @ 10kg) |
Power |
N/A 115 VAC, 60 Hz 220 VAC, 50 Hz |
Output Options |
N/A 4-20mA non-isolated |
Alarms |
N/A Audible alarm with 'Acknowledge' button Dual high CO alarm light and relays (SPDT - 5A@ 230 VAC) Strobe light and/or large audible alarm horn available |
Analyzer Type |
N/A Ambient CO analyzer |
Area Rating |
N/A General Purpose Non-Hazardous only |
N/A Designed to monitor carbon monoxide (CO) in underground parking garages, service garages, around steel making furnaces, breathing air, or any other area where CO may be present. |
N/A
|
N/A
|
N/A The 580 Series is not suitable for process or flue gas CO analysis. All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova at 1-800-295-3771. In many cases, we are able to build an analyzer specific to your needs. |