The Model 203 Series Portable Dew Point Analyzers have been designed primarily for accurate dew point measurement of dry non-corrosive industrial gases, or dry oil-free air. The aluminum oxide sensing element varies its electrical capacitance in direct proportion to variations in the sample gas dew point.

The 203 Series can have either a built-in pressure regulator for positive pressure samples, or a built-in sample pump for atmospheric pressures, or both. The sample flow is shown on a flowmeter on the front or top panel. The dew point is shown on a touchscreen display. A 4-20mA output is optionally available. Some models have rechargeable battery operation. Please contact Nova for the correct version for your application.



Models:
  • 203K - suitcase cabinet with display on inside; display visible when case is opened
  • 203KX - suitcase cabinet with display on outside; display visible when case is closed
  • 230BT - rectangular bench top style cabinet
Unit of Measure

Specifications

Features

N/A
  • Low range of -112° to +68°F (or -80° to +20°C) Dew Point
  • Easy to operate; long-life sensor
  • Fast warm-up and response
  • Use on any non-corrosive industrial gases or air
  • Built-in sample pump, filter, and flow meter
  • Blocking solenoids used to trap low DP gas in cell for quick purge down and to protect cell when not in use, or during initial sample line purge
  • Touch-screen display of gas readings
  • Rechargeable battery operation
  • Suitcase style case with choice of display locations

SPECIFICATIONS

N/A Method of Detection: Aluminum oxide capacitance sensor
Ranges Available: -80° to +20°C or -112° to +68°F
Resolution: 1°
Accuracy and Repeatability:
± 1°C from -60° to +20°C Dew Point; ± 2°C from -80° to -60°C
± 1°F from -76° to +68°F Dew Point; ± 2°F from -112° to -76°F
Drift:
± 0.5°C Dew Point max. for temperatures between -29 to +4°C
± 1°F Dew Point max. for temperatures between -20 to +40°F
Response Time (T-90):
Less than 30 seconds at higher dew points;
Lower dew points may take up to 1 minute (sensor must be in pre-dried state)
Ambient Temperature Range: 0° to 120°F (-18° to 50°C)
Linearity: ± 2°F / C over measurement range
Size and Weight:
K style - approx. 35 x 15 x 17 cm @ 5.5 kg (14" W x 6" H x 6½" D @ 12 lbs)
Power:
115VAC 60 Hz for recharging (230VAC 50 HZ also available)
Output: 4-20mA

(Nova reserves the right to specification changes which may occur with advances in design without prior notice.)

Applications

Applications

N/A Steel and Metal Heat-Treating

Options

Options

N/A • 4-20mA recorder output
• Built-in sample pump or pressure regulator
• Data logging
• Type 'K' suitcase style cabinet, internal display
• Type 'KX' suitcase style cabinet, external display

Measurement Range

Measurement Range

N/A -112°F to +86°F  or  -80°C to +20°C