Method of Detection |
N/A Catalytic oxidation detector for combustibles; expected life is 3-4 years for each Customer replaceable electrochemical O2 and CO sensors |
Ranges Available |
N/A 0-1800°F or 0-1000 °C stach temperature (Model 352T) 0-2000PPM and 4.00% CO (switch selectable) 0-25.0% O2 0-5.0% or 0-10.0% combustibles |
Resolution |
N/A 0.1% O2, CO and combustibles |
Accuracy & Repeatability |
N/A ±1% full scale, based on 20.9% O2; ± 2% of full scale combustibles |
Drift |
N/A <2% full scale per 8 hours of continuous operation |
Response Time |
N/A 5-8 seconds for O2; 20-30 seconds for combustibles |
Ambient Temperature Range |
N/A 0 to 40.5 ºC32 to 105 ºF |
Linearity |
N/A ±1% full scale O2 and CO; ±2% of full scale combustibles |
Size & Weight |
N/A 11 1/2" L x 8W" W x 7 1/4" H @ 8 lbs (29 x 20 x 18.6 cm @ 3.6 kg) |
Power |
N/A AC/DC Operation, 115 VAC, 60 Hz for recharging (Other voltages available) |
Output Options |
N/A 4-20 mA or 0-1 VDC |
Hazardous Area Rating Options |
N/A General Purpose, Non-Hazardous |
N/A
|
N/A
|
N/A
|
N/A
|
N/A
All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova. In many cases, we are able to build an analyzer specific to your needs. |