Model 420N4 Model 420N4 Carbon Dioxide Analyzer, Wall Mounted NEMA4 (IP65) Enclosure Rating |
Model 420N4N7 Model 420N4N7 Carbon Dioxide Analyzer, ex-proof sensor housing with NEMA4 wall-mount control cabinet (two separate enclosures) |
Model 420N7MC Model 420N7MC Carbon Dioxide Analyzer, in Explosion-proof cabinet, Class 1 Div 1 Group BCD |
Model 420RMN7 Model 420RMN7 Carbon Dioxide Analyzer, ex-proof sensor housing with rack mount control cabinet (two separate enclosures) |
Model 420 D1 or D2 Model 420 D1 or D2 Carbon Dioxide Analyzer, with cabinet purge systems for hazardous areas |
|||||
Method of Detection | N/A Single cell NDIR with no moving parts | |||||||||
Ranges Available | N/A 420 - 0-1, 0-5, 0-10, 0-20, 0-30, 0-50, 0-100% CO2 420L - 0-5,000 PPM CO2 420L-LP - 0-500, 1000, 2000, 5000, 10000 PPM (may be available, check with NOVA) | N/A 420 - 0-1, 0-5, 0-10, 0-20, 0-30, 0-50, 0-100% CO2 420L - 0-5,000 PPM CO2 | N/A 420 - 0-1, 0-5, 0-10, 0-20, 0-30, 0-50, 0-100% CO2 420L - 0-5,000 PPM CO2 | N/A 420 - 0-1, 0-5, 0-10, 0-20, 0-30, 0-50, 0-100% CO2 420L - 0-5,000 PPM CO2 | N/A 420 - 0-1, 0-5, 0-10, 0-20, 0-30, 0-50, 0-100% CO2 420L - 0-5,000 PPM CO2 420L-LP - 0-500, 1000, 2000, 5000, 10000 PPM (may be available, check with NOVA) | |||||
Accuracy & Repeatability | N/A ±1-3% of full scale, depending on measurement range and application | |||||||||
Drift | N/A Usually 2% of full scale per month or less, depending on range and application | |||||||||
Response Time (T-90) | N/A Usually 20-30 seconds to 90% step change, depending on range and application | |||||||||
Ambient Temperature Range | N/A 40 to 104°F (4 to 40°C). Optional: up to 130°F (55°C) with cabinet cooler | N/A 40 to 104°F (4 to 40°C). | N/A 40 to 104°F (4 to 40°C). Optional: up to 130°F (55°C) with cabinet cooler | N/A 40 to 104°F (4 to 40°C) | N/A 40 to 104°F (4 to 40°C). Optional: up to 130°F (55°C) with cabinet cooler | |||||
Linearity | N/A Usually ±1.5% of full scale, depending on range and application | N/A Usually ±1.5% of full scale, depending on range and application | N/A Usually ±1.5% of full scale, depending on range and application | N/A Usually ±1.5% of full scale, depending on gas measured | N/A Usually ±1.5% of full scale, depending on gas measured | |||||
Size & Weight | N/A NEMA 4: 51H x 41W x 26D cm (20"H x 16"W x 10"D) RACK MOUNT: 22H x 48W x 47D cm (8.7"H x 19"W x 16"D) | N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) NEMA 4: 51H x 41W x 26D cm (20"H x 16"W x 10"D) | N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) | N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) RACK MOUNT: 22H x 48W x 47D cm (8.7"H x 19"W x 16"D) | N/A NEMA 4: 61H x 51W x 31D cm (24"H x 20"W x 12"D) (not including purge panel & vent) | |||||
Power | N/A 115 VAC, 60 Hz 220 VAC, 50 Hz | |||||||||
Alarms | N/A High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating Low flow alarm | |||||||||
Options | N/A Cabinet coolers can be fitted to most models Hi/Low gas, Low Flow alarms available High temperature filters and probes Light duty sample conditioning systems available for removal of moisture and dust | N/A Hi/Low gas, Low Flow alarms available High temperature filters and probes | N/A Cabinet coolers can be fitted to most models Cabinet purge system available for use in hazardous areas Cold weather package for operation to -5°F (-20°C) Full automatic calibration with touch screen LCD display Hi/Low gas, Low Flow, and diagnostic alarms available High temperature filters and probes Isolated analog, RS232, RS485, MODBUS, and Ethernet outputs available One-step 'cal-now' button with touch screen LCD display Sample conditioning systems available for removal of moisture, acidic gas, and dust Sensor mounted in temperature controlled heated box to improve accuracy | N/A Hi/Low gas, Low Flow, alarms available High temperature filters and probes | N/A Cabinet coolers can be fitted to most models Cabinet purge system available for use in hazardous areas Hi/Low gas, Low Flow, alarms available High temperature filters and probes Light duty sample conditioning systems available for removal of moisture and dust | |||||
Analyzer Type | N/A CO2 Gas Analyzer | |||||||||
Hazardous Area Rating Options | N/A General Purpose, Non-Hazardous | N/A Control Cabinet - General Purpose, Non-Hazardous Detector Cabinet - NEMA7 Class 1 Division 1 Groups BCD | N/A Class 1, Div 1, Grp A-D Hazardous Area Rating | N/A Control Cabinet - General Purpose, Non-Hazardous Detector Cabinet - NEMA7 Class 1 Division 1 Groups BCD | N/A Class 1 Div 2 or Class 1 Div 1 Hazardous Area Ratings available | |||||
|