Items |
Model 352WP Portable Flue Gas Analyzer for Oxygen, Carbon Monoxide & Combustibles, Weatherproof (WP) Enclosure |
Model 352K Portable Flue Gas Analyzer for Oxygen, Carbon Monoxide & Combustibles, Suitcase (K) Enclosure |
||
Method of Detection | N/A Catalytic oxidation detector for combustibles; expected life is 3-4 years for each Customer replaceable electrochemical O2 and CO sensors | |||
Ranges Available | N/A 0-1800°F or 0-1000 °C stach temperature (Model 352T) 0-2000PPM and 4.00% CO (switch selectable) 0-25.0% O2 0-5.0% or 0-10.0% combustibles | |||
Resolution | N/A 0.1% O2, CO and combustibles | |||
Accuracy & Repeatability | N/A ±1% full scale, based on 20.9% O2; ± 2% of full scale combustibles | |||
Drift | N/A <2% full scale per 8 hours of continuous operation | |||
Response Time | N/A 5-8 seconds for O2; 20-30 seconds for combustibles | |||
Ambient Temperature Range | N/A 0 to 40.5 ºC32 to 105 ºF | |||
Linearity | N/A ±1% full scale O2 and CO; ±2% of full scale combustibles | |||
Size & Weight | N/A 11 1/2" L x 8W" W x 7 1/4" H @ 8 lbs (29 x 20 x 18.6 cm @ 3.6 kg) | N/A 14" L x 10 1/2" W x 6" H @ 8 lbs (36 x 27 x 15 cm @ 5.5 kg) | ||
Power | N/A AC/DC Operation, 115 VAC, 60 Hz for recharging (Other voltages available) | |||
Output Options | N/A 4-20 mA or 0-1 VDC | N/A 0-1 VDC 4-20 mA | ||
Options | N/A AC power only operation Data Logger High temperature probes Recorder outputs of 0-1 V or 4-20 mA (can be isolated) Sample pre-cooler Suitcase (K) style cabinet available | |||
Analyzer Type | N/A Combustion Analyzer | |||
Hazardous Area Rating Options | N/A General Purpose, Non-Hazardous | |||
|