Print Back
The Model 309 Series Portable Flue Gas Analyzer has been designed for accuracy, reliability and ease of use and service. The 309 uses a long life electrochemical O2 sensor and a solid state infra red CO2 detector, both of which respond quickly to O2 and CO2 present in the flue gas sample.

In operation, a built-in sample pump draws in the flue gas sample through the S.S. probe, 12 ft sample hose, condensate removal filter, secondary filter and flow meter then on to the O2 sensor and CO2
more
Unit of Measure

Specifications

Method of Detection

Electrochemical O2 sensor Infrared detector for CO2

Ranges Available

0-5000 ppm; 0-1%; 0-10%; 0-20%; 0-50%; 0-100% CO2
0-25% O2

Resolution

0.1% O2 and CO2

Accuracy & Repeatability

Within ±2% full scale

Drift

Within 1% full scale per 8 hours of continuous operation

Response Time (T-90)

O2 less than 10 seconds; CO2 less than 30-40 seconds to T-90

Ambient Temperature Range

4 to 49 ºC40 to 120 ºF

Linearity

±1.0% of full scale

Size & Weight

K Style - 14" L x 10 1/2" W x 6" H @ 12 lbs ( 36 x 27 x 15 cm @ 5.5 kg) WP Style - 11 1/2" L x 8" W x 7 1/4" H @ 8 lbs (29 x 20 x 18 cm @ 3.6 kg)

Power

AC/DC Operation, 115 VAC, 60 Hz for recharging

Output Options

0-1 VDC 4-20 mA

Unique Applications

    All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova. In many cases, we are able to build an analyzer specific to your needs.

Primary Gas to be Measured

Carbon Dioxide (CO2) Oxygen (O2)

Industry Type

Flue Gas or Emissions

Applications

N/A

    Analysis of Carbon Dioxide (CO2) and Oxygen (O2). For checking combustion efficiency, burner & control performance of furnaces, heaters and boilers in commercial, industrial and residential applications.

Features

N/A

  • Rugged design that is easy to operate
  • Fast warm-up and response
  • Solid state infrared detector CO2
  • Long-life electrochemical sensor for O2
  • Digital readout meter with backlight
  • Modular layout that is easy to maintain
  • Rechargeable battery operation
  • Stainless steel probe with sample hose
  • Built in sample pump, filter and flow meter
  • Weatherproof (WP) cabinet with clear Lexan cover

Options

N/A

  • Recorder outputs of 0-1 V or 4-20 mA
  • Sample pre-cooler for hot samples
  • Condensate removal for wet applications
  • Suitcase (K) style cabinet available
  • AC power only operation
  • CO2 and O2 alarms with LED
  • Data logger

Calibration

N/A

  • Air for CO2 zero and O2 span
  • Analyzed calibration gas for CO2 span and O2 zero