Range 1: 0-100.0% H2 in Air
Range 2: 0-100.0% H2 in CO2
Range 3: 0-100.0% Air in CO2
A 4-20mA recorder output is provided for the range of 85-100% H2 in Air.
The Model 436 analyzer is typically available in a single ex-proof cabinet with all capabilties built-in. Or, it may be divided into 2 sections that are electrically connected. The control section contains the main microprocessor boards as well as the touch-screen display, alarm contacts, and calibration & function switches. The gas detector section contains the temperature controlled thermal-conductivity (TC) cell, solenoid valves, gas pressure regulator, flow meter, and 2 flame arrestors.
Either the gas detector section on its own or both gas detector and control sections may be purchased in explosion-proof cabinets. The explosion-proof cabinets are UL listed and CSA certified for use in Class 1, Division 1, Groups BCD hazardous areas. If the gas detector section only is explosion-proof, the control section is typically enclosed in a 19" rack mount cabinet for use in a general purpose, non-hazardous area. The control section can also be mounted in a NEMA 4 wall mount cabinet.
Cabinets, 436N4N7: Gas Detector in Class 1, Division 1, Groups BCD Explosion-proof Cabinet; Control Section in General Purpose NEMA 4 Cabinet
Specifications
Method of Detection |
N/A Temperature controlled thermal conductivity (T/C) cell, cannot be burned out due to loss of flow or changing gases |
Ranges Available |
N/A Range 1 : 0-100% H2 in Air Range 2 : 0-100% H2 in CO2 Range 3 : 0-100% Air in CO2 |
Resolution |
N/A ±0.1% of gas measured |
Accuracy & Repeatability |
N/A ±1% F.S except in 85-100% H2 in Air range which is within 0.2% absolute H2 |
Drift |
N/A H2 in CO2 or Air in CO2 1% F.S. per week maximum drift, 0-100% H2 in Air range is ±0.2% per week |
Response Time (T-90) |
N/A 10-15 seconds to 90% step change - not including sample transport time |
Ambient Temperature Range |
N/A 0 to 49 ºC32 to 122 ºF |
Linearity |
N/A ±0.4% of F.S. on H2 in Air range, ±1% of F.S. in H2 or Air in CO2 ranges |
Size & Weight |
N/A Control: NEMA 4: 51H x 41W x 26D cm (20"H x 16"W x 10"D) Detector: EX-PROOF: 33H x 33W x 31H cm (13"H x 13"W x 12"D) |
Power |
N/A 115 VAC, 60 Hz 220 VAC, 50 Hz |
Output Options |
N/A 4-20mA into 500 ohms non-isolated standard |
Alarms |
N/A H2 purity alarm |
Analyzer Type |
N/A Tri-Gas Analyzer |
Hazardous Area Rating Options |
N/A Control Cabinet - General Purpose, Non-Hazardous Detector Cabinet - NEMA7 Class 1 Division 1 Groups BCD |
Applications
N/A For continuous analysis of hydrogen (H2) purity and for purge monitoring of hydrogen-cooled generators and synchronous converters. |