For continuous analysis of oxygen (O2), methane (CH4), and/or carbon dioxide (CO2) in recovered gases from landfill sites.
Cabinet: NEMA 4 cabinet with Hazardous Area Purge System; available for Class 1 Div1 & Div2 hazardous areas
Specifications
Method of Detection |
N/A Long life electrochemical O2 sensor, field-cleanable infrared CH4 & CO2 detector |
Ranges Available |
N/A 0-25.0% O2; any range between 0-50.0% and 0-100.0% CH4, CO2 |
Resolution |
N/A 0.1% on CO2, O2, & CH4 |
Accuracy & Repeatability |
N/A ±1% of full scale |
Drift |
N/A Less than 2% of full scale per month |
Response Time (T-90) |
N/A Less than 30 seconds not including sample line delay |
Ambient Temperature Range |
N/A 40 to 120°F (4 to 48°C), Lower temperatures (-5°F, -20°C) with Cold Weather Package |
Linearity |
N/A ±1% of full scale for each gas measured |
Size & Weight |
N/A 24" H x 20" W x 10" D @ 90 lbs (61 x 51 x 25 cm @ 20 kg) Physical data may vary depending on options required |
Power |
N/A 115 VAC, 60 Hz 220 VAC, 50 Hz |
Output Options |
N/A 4-20 mA into 500 ohms non-isolated standard Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs |
Alarms |
N/A High O2, high CO2, low CH4, low flow; SPDT relays with 10A contacts |
Analyzer Type |
N/A Landfill Gas Analyzer |
Other Analysis Options |
N/A BTU - BTU readout, range 0-1000 BTU H1 - H2S, range 0 - 200 PPM H2 - H2S, range 200 - 5000 PPM H3 - H2S, range 1000 - 10000 PPM (if no CO2 in sample) H4 - H2S, range 1000 - 10000 PPM (if CO2 is in sample) |
Hazardous Area Rating Options |
N/A Class 1, Division 2 Group BCD |
Applications
N/A
|
Features
N/A
|
Options
N/A
|