New Call-to-action
The Nova FLEXI-NOVA Series Platform has been designed for continuous gas measurements in applications and environments that are less intensive. Lab work, research, clean processes, pre-treated / pre-cleaned produced gases, and others, may benefit from the FLEXI-NOVA series.

Depending on application, some light-duty sample conditioning features may be available. For clean process measurements, percent-level H2 gas. This analyzer utilizes a temperature-controlled, thermalconductivity (TC) cell for the detection of H2 in process gas. The cell produces a small millivoltage output which is directly proportional to the H2 detected. The analyzer can be supplied with a pump or pressure regulator depending on customer requirement.

All sensors / detectors are temperature-controlled or temperature-compensated for maximum analytical stability. Easy calibration using touch-screen controls. Serial Output Package allows local USB connection & data-logging to personal computers.

Cabinet: Wall Mounted NEMA7 UL/CSA Explosion-proof sensor cabinet with NEMA4 wall-mount control cabinet (two separate cabinets)
Unit of Measure

Specifications

Method of Detection

N/A Temperature-controlled TC cell. Expected life in excess of 10 years. Cell cannot be burned out due to loss of sample flow

Ranges Available

N/A Any range between 0-2% and 0-100% H2

Resolution

N/A 0.1% H2 (0.01% H2 available)

Accuracy & Repeatability

N/A ±1% of full scale

Drift

N/A Less than 1% of full scale per month

Response Time (T-90)

N/A 10-15 seconds to 90% step change

Ambient Temperature Range

N/A 40 to 104°F (4 to 40°C). Optional: up to 130°F (55°C) with cabinet cooler.

Linearity

N/A ±1% of full scale

Size & Weight

N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) NEMA 4: 51H x 41W x 26D cm (20"H x 16"W x 10"D)

Power

N/A 115 VAC, 60 Hz 220 VAC, 50 Hz

Output Options

N/A 4-20 mA into 500 ohms non-isolated standard Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs

Alarms

N/A High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating

Analyzer Type

N/A H2 Analyzer

Hazardous Area Rating Options

N/A Control Cabinet - General Purpose, Non-Hazardous Detector Cabinet - NEMA7 Class 1 Division 1 Groups BCD

Applications

N/A Light-duty analyzers for applications or environments that are less intensive. For continuous analysis of up to 100% hydrogen (H2) in clean process gas streams.

Features

N/A

  • Best value continuous H2 analyzer
  • Local digital readout, 4-20mA recorder output
  • Long life thermal conductivity (TC) detector with high accuracy and repeatability, cannot be burned out from loss of flow
  • Easy-to-maintain, modular layout, fast response
  • Built-in sample pump or pressure regulator
  • Sensor temperature-controlled for maximum stability

Options

N/A

  • Hi/Low gas and low flow alarms available
  • Serial output & data-logger package available

Calibration

N/A

  • Nitrogen or air for zero
  • Span using a known H2 in nitrogen calibration gas.

Unique Applications

N/A

    All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova. In many cases, we are able to build an analyzer specific to your needs.

View Our
Product Catalog
Have a question?
Contact Us
Ready to get started?
Request Quote