The 'DR' models are configured such that the oxygen sensor(s) are mounted outside of, and electrically connected to, the main cabinet (max distance between remote sensor & main cabinet - 50ft). This allows allows O2 monitoring of single or multiple remote zones, with centralized display and alarming features. The remote sensors are the diffusion type, with no pump or moving parts.
Optional dual level alarm with local indication, relay contacts, and audible alert available. Alarm set points are pre-set at Nova but are field adjustable if desired. Flashing strobe light and upgraded cabinets also available.
Models:
- 510DR1 - Control cabinet with one remote diffusion sensor
- 510DR2 - Control cabinet with two remote diffusion sensors
- 510DR3 - Control cabinet with three remote diffusion sensors
- 510DR4 - Control cabinet with four remote diffusion sensors
Specifications
Method of Detection |
N/A Customer replaceable electrochemical oxygen sensor |
Ranges Available |
N/A 0-30% O2 |
Resolution |
N/A 0.1% O2 |
Accuracy & Repeatability |
N/A ± 2% of full scale |
Drift |
N/A Less than 1% of full scale per month |
Response Time (T-90) |
N/A 6-8 seconds to 90% step change |
Ambient Temperature Range |
N/A 40° to 104°F (5° to 40°C) |
Linearity |
N/A ± 2% of full scale |
Size & Weight |
N/A 20" H x 16" W x 10" D @ 20lbs. (51 x 41 x 26 cm @ 10kg) |
Power |
N/A 115 VAC, 60 Hz 220 VAC, 50 Hz |
Output Options |
N/A 4-20mA non-isolated |
Alarms |
N/A Optional High and/or Low O2 alarm with SPDT contacts with 10A 115VAC rating |
Analyzer Type |
N/A Ambient O2 analyzer |
Area Rating |
N/A General Purpose Non-Hazardous only |
Applications
N/A To monitor confined spaces, labs, control rooms, tunnels, oxygen plants, etc. for oxygen (O2) deficiency or excess. |
Features
N/A
|
Options
N/A
|
Product Catalog
Contact Us