Cabinet: Wall Mounted NEMA7 UL/CSA Explosion-proof with Non-intrusive Magnetic Calibration, Class 1 Div 1 Group BCD. Availability depends on application and environment. Sample conditioning options not available with this cabinet style.
Specifications
Method of Detection |
N/A Low range PPM SO2 by electrochemical sensor Microprocessor based single cell NDIR |
Ranges Available |
N/A 460 - 0-1, 0-5, 0-10% SO2 460L - 0-200, 0-1000 PPM SO2 (check availability with Nova) |
Resolution |
N/A 0.1% SO2 on % versions, 10 PPM SO2 on PPM versions |
Accuracy & Repeatability |
N/A 1-2% of full scale |
Drift |
N/A Less than 2% of full scale per month |
Response Time (T-90) |
N/A 15-30 seconds to T-90 |
Ambient Temperature Range |
N/A 40 to 104°F (4 to 40°C). |
Linearity |
N/A ±1% of full scale |
Size & Weight |
N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) |
Power |
N/A 115 VAC, 60 Hz 220 VAC, 50 Hz |
Output Options |
N/A 4-20mA into 500 ohms non-isolated standard Isolated 4-20mA, RS232, RS485, serial outputs |
Alarms |
N/A High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating Low flow alarm |
Analyzer Type |
N/A SO2 Analyzer |
Hazardous Area Rating Options |
N/A Class 1, Div 1, Grp A-D Hazardous Area Rating |
Applications
N/A For continuous analysis of sulfur dioxide (SO2) in process gas streams using an infrared detector. Percent and PPM levels available as Models 460 & 460L respectively. |
Features
N/A
|
Calibration
N/A
|
Unique Applications
N/A Nova 460 / 461 analyzers are suitable for clean dry process gases only. Some gases may interfere with SO2 measurement; complete information on sample gas composition is required. All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova at 1-800-295-3771. In many cases, we are able to build an analyzer specific to your needs. |
Product Catalog
Contact Us
Request Quote