New Call-to-action
The Nova 420 Series CO2 analyzers utilize a simple and reliable microprocessor-based non-dispersive infrared detector specific to CO2. The detector pulses an infrared beam of light through the sample tube, without the need for a mechanical chopper. In operation, the internal sample pump draws the sample gas through the filter/condensate trap, secondary filter, flow meter, and then on to the infrared detector. The detector output is digitally linearized and then displayed as percent CO2 on the digital meter. The output is also available as an analog or digital signal.
Unit of Measure

Specifications

Method of Detection

N/A Single cell NDIR with no moving parts

Ranges Available

N/A 420 - 0-1, 0-5, 0-10, 0-20, 0-30, 0-50, 0-100% CO2 420L - 0-500, 0-1000, 0-3000, 0-5000, PPM CO

Resolution

N/A 0.1% CO2 on % versions, 1 PPM CO2 on PPM versions

Accuracy & Repeatability

N/A 1% of full scale

Drift

N/A Less than 1% of full scale per month

Response Time (T-90)

N/A Less than 15 seconds

Ambient Temperature Range

N/A 40 to 122°F (5 to 50°C), Lower temperatures (-5°F, -20°C) available with Cold Weather Package

Linearity

N/A ±1% of full scale

Size & Weight

N/A Physical data will vary depending on enclosure style and options required

Power

N/A 115 VAC, 60 Hz 220 VAC, 50 Hz

Output Options

N/A 4-20 mA into 500 ohms non-isolated standard Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs

Alarms

N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating Low flow alarm

Analyzer Type

N/A CO2 Gas Analyzer

Hazardous Area Rating Options

N/A Class 1, Div 1, Grp A-D Hazardous Area Rating

Applications

N/A

    For continuous analysis of carbon dioxide (CO2) in process gas streams using an infrared detector. Percent and PPM levels available as Models 420 & 420L respectively.

Features

N/A

  • PPM or percent CO2 by infrared detector
  • Detector is sensitive, very reliable, and non-depleting
  • Bright digital readout, 4-20 mA outputs
  • Fast response (T90 - less than 15 seconds)
  • Microprocessor control for push button calibration
  • Easy-to-maintain modular layout
  • Built in sample pump, flowmeter and filters

Options

N/A

  • Hi/Low gas, low flow, and diagnostic alarms available
  • Isolated analog, RS232, RS485, MODBUS, and Ethernet outputs available
  • Sample conditioning systems available for removal of moisture, acidic gas, and dust
  • Cabinet purge system available for use in hazardous areas
  • One-step 'cal-now' button with touch screen LCD display
  • Full automatic calibration with touch screen LCD display
  • Cold weather package for operation to -5°F (-20°C)
  • Cabinet coolers can be fitted to most models
  • Sensor mounted in temperature controlled heated box to improve accuracy
  • High temperature filters and probes

Calibration

N/A

  • Easily zero checked on ambient air or nitrogen (N2)
  • Span using a known CO2 in nitrogen calibration gas.

Unique Applications

N/A

    The 420 Series analyzers are designed for detection of CO2 in non-corrosive gas streams. All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova. In many cases, we are able to build an analyzer specific to your needs.

View Our
Product Catalog
Have a question?
Contact Us
Ready to get started?