In operation, a built in sample pump draws in the flue gas sample through the S.S. probe, 12 ft. sample hose, condensate removal filter, secondary filter, flow meter, and then on to the three sensors. The detected O2, CO, and NO are displayed on a digital meter.
The Nova 362 can also optionally indicate net stack temperature for doing fuel efficiency calculations (362T). The temperature sensor is built into the sampling probe. Efficiency charts for each fuel are provided.
A rechargeable battery provides enough power for about 8 hours of operation and the analyzer can be used while it is being recharged. The battery recharger is included with the analyzer.
Specifications
Method of Detection |
N/A Customer replaceable electrochemical O2, CO and NO sensor |
Ranges Available |
N/A 0-200 to 0-2000 PPM NOx (as NO); 0-1800°F (0-1000°C) net stack temperature (362T) 0-25.0% O2; 0-2000 PPM to 0-4.00% CO (switch selectable) |
Resolution |
N/A 0.1% O2; 1 PPM on CO and NOx |
Accuracy & Repeatability |
N/A <1% of O2; ± 10 PPM CO; ± 3 PPM NOx |
Drift |
N/A ±2% of full scale per 8 hours of continuous operation |
Response Time (T-90) |
N/A 10-12 seconds for O2; 20-30 seconds for CO and NOx |
Ambient Temperature Range |
N/A 0 to 40 ºC32 to 105 ºF |
Linearity |
N/A ±1% of full scale of each gas measured |
Size & Weight |
N/A approx. 26 x 18 x 13 cm @ 3.4 kg (10" x 7" x 5" @ 7.5lbs) |
Power |
N/A 115VAC 60Hz for recharging (220VAC 50Hz available) |
Output Options |
N/A 4-20mA |
Hazardous Area Rating Options |
N/A General Purpose, Non-Hazardous |