The Nova 376 Series Portable Analyzers provide a detailed analysis of flue gas composition. They have been designed for accuracy, reliability, and ease of use and service. The sensors respond quickly to the gases of interest present in the flue gas sample. Under normal conditions of use, the O2, CO and NOx sensors each have a life expectancy of between 3 and 4 years and are customer-replaceable. The CO2 sensor should not need to be replaced.

In operation, a built in sample pump
more
Unit of Measure

Specifications

Method of Detection

Customer replaceable electrochemical O2, CO and NO sensors Solid state infrared detector for CO2

Ranges Available

0-1800°F (0-1000°C) stack temperature 0-20.0% CO2 0-200 to 0-2000 PPM NOx (as NO) ranges available 0-2000 PPM and 0-4.00% CO - Switch selectable 0-25.0% O2

Accuracy & Repeatability

Within ±0.1% O2 and CO2; ±10 PPM CO and NO

Drift

2% full scale per 8 hours of continuous operation

Response Time (T-90)

10-15 seconds for O2; 20-30 seconds for CO, NO, and CO2

Ambient Temperature Range

0 to 40 ºC32 to 105 ºF

Linearity

±1.0% of full scale for each gas measured

Size & Weight

18" L x 7" H x 12" D @ 15 lbs (45.7 x 30.5 x 17.8 cm @ 6.8 kg)

Power

AC/DC Operation, 115 VAC, 60 Hz for recharging

Output Options

0-1 VDC 4-20 mA

Hazardous Area Rating Options

General Purpose, Non-Hazardous

Applications

N/A

    Analysis of oxygen (O2), carbon monoxide (CO), carbon dioxide (CO2) and oxides of nitrogen (NOx as NO). For checking the combustion efficiency and burner & control performance of furnaces, heaters, and boilers. May be used in commercial, industrial, and residential settings.

Features

N/A

  • Rugged design that is easy to operate and maintain
  • Fast warm up and response
  • CO2 actually measured by infra-red detector, not calculated
  • Dual CO range : 0-2000 ppm & 0-4.00%
  • Rapid reading recovery after CO or NO 'overdose'
  • Digital readout meters with backlight
  • Rechargeable battery operation
  • Built in sample pump, filter and flow meter
  • Active condensate removal
  • Weatherproof (WP) cabinet with clear Lexan cover
  • Stainless steel probe with sample hose
  • Use on any fuel

Options

N/A

  • Outputs of 0-1 V or 4-20 mA (can be isolated)
  • Stack temperature readout (376T)
  • Special sampling probes
  • Suitcase (K) style cabinet available
  • AC power only operation
  • Gas alarms with LED
  • Detachable/portable data logger

Calibration

N/A

  • Air for O2 span and CO/CO2 zero
  • Analyzed gas mixtures of CO2, CO, and NOx in nitrogen for span

Unique Applications

N/A

    The 376 Series should not be used for detecting these gases in ambient atmospheres for personnel safety purposes. All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova. In many cases, we are able to build an analyzer specific to your needs.