The Nova 360 Series are portable analyzers that can provide a detailed analysis of flue gas composition. They have been designed to be accurate, reliable, and easy to use and maintain. The sensors respond quickly to the oxygen and carbon monoxide (CO) present in the flue gas sample. The typical sensor life expectancy is between 3-4 years and they are customer-replaceable.
In operation, a built-in sample pump draws in the flue gas sample through the S.S. probe, 12 ft. sample hose,more condensate removal filter, secondary filter and flow meter, then on to the three sensors. The detected O2 and CO are displayed on a digital meter.
The Nova 360T indicates net stack temperature for doing fuel efficiency calculations. The temperature sensor is built into the sampling probe. Efficiency charts for each fuel are provided.
A rechargeable battery provides enough power for about 8 hours of operation and the analyzer can be used while it is being recharged. Recharger is included with the analyzer. less
In operation, a built-in sample pump draws in the flue gas sample through the S.S. probe, 12 ft. sample hose,more condensate removal filter, secondary filter and flow meter, then on to the three sensors. The detected O2 and CO are displayed on a digital meter.
The Nova 360T indicates net stack temperature for doing fuel efficiency calculations. The temperature sensor is built into the sampling probe. Efficiency charts for each fuel are provided.
A rechargeable battery provides enough power for about 8 hours of operation and the analyzer can be used while it is being recharged. Recharger is included with the analyzer. less
Unit of Measure
Specifications
Method of Detection |
N/A Customer replaceable electrochemical O2 and CO sensors |
Ranges Available |
N/A 0-1800°F (0-1000°C) net stack temperature 0-25.0% O2, 0-2000 PPM to 0-4.00% CO (switch selectable) |
Resolution |
N/A 0.1% O2, 1 PPM CO |
Accuracy & Repeatability |
N/A ±1% of O2, ± 1 PPM CO |
Drift |
N/A ±1% of full scale per 8 hours of continuous operation |
Response Time (T-90) |
N/A 10-15 seconds for O2 and CO |
Ambient Temperature Range |
N/A 0 to 40 ºC32 to 105 ºF |
Linearity |
N/A ±1% of full scale of each gas measured |
Size & Weight |
N/A approx. 26 x 18 x 13 cm @ 3.4 kg (10" x 7" x 5" @ 7.5lbs) |
Power |
N/A 12V battery operation. 115VAC 60Hz for recharging (220VAC 50Hz available) |
Output Options |
N/A 4-20mA |
Hazardous Area Rating Options |
N/A General Purpose, Non-Hazardous |