Method of Detection |
N/A Catalytic oxidation detector for combustibles. Expected life is 2-3 years for each Customer replaceable electrochemical O2 sensor |
Ranges Available |
N/A 0-1800°F or 0-1000°C stack temperature (Model 350T) 0-25.0% O2 0-5.0% or 0-10.0% combustibles |
Resolution |
N/A 0.1% O2 and combustibles |
Accuracy & Repeatability |
N/A ±1% full scale, based on 20.9% O2; ± 2% of full scale combustibles |
Drift |
N/A <2% full scale per 8 hours of continuous operation |
Response Time (T-90) |
N/A 5-8 seconds for O2; 20-30 seconds for combustibles |
Ambient Temperature Range |
N/A 0 to 40.5 ºC32 to 105 ºF |
Linearity |
N/A ±1% full scale, based on 20.9% O2; ± 2% of full scale combustibles |
Size & Weight |
N/A K Style: 14" L x 10 1/2" W x 6" H @ 12 lbs (36 x 27 x 15 cm @ 5.5 kg) WP Style: 10" L x 7 1/2" H x 8" D @ 8 lbs (25 x 19 x 20 cm @ 3.6 kg) |
Power |
N/A AC/DC Operation, 115 VAC 60 Hz for recharging (Other voltages available.) |
Output Options |
N/A 4-20 mA or 0-1 VDC |
Unique Applications |
N/A The 350 Series should not be used for detecting these gases in ambient atmospheres for personnel safety purposes. All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova. In many cases, we are able to build an analyzer specific to your needs. |
Primary Gas to be Measured |
N/A Oxygen (O2) |
Industry Type |
N/A Flue Gas or Emissions |