Items |
Model 415N7MC Model 415N7MC Trace Oxygen Analyzer, Wall Mounted NEMA7 UL/CSA Explosion-proof, Class 1 Div 1 Group BCD |
Model 415RMN7 Model 415RMN7 Trace Oxygen Analyzer, ex-proof sensor housing with rack mount control cabinet (two separate enclosures) |
Model 415 D1 or D2 Model 415 D1 or D2, Trace Oxygen Analyzer with cabinet purge systems for hazardous areas |
|||
Method of Detection | N/A Customer replaceable 'fuel cell' oxygen sensor | |||||
Ranges Available | N/A Any range between 0-100 PPM and 0-10000 PPM | |||||
Resolution | N/A 1 PPM | |||||
Accuracy & Repeatability | N/A ±1% of full scale | N/A ±1% of full scale | N/A ±1% of full scale | |||
Drift | N/A Less than 1% of full scale per week | |||||
Response Time (T-90) | N/A In some cases, ppmO2 sensor may require an initial purge-down from air to low PPM O2 which may last 1-2 hours. After purge, T90 response O2 is less than 20 seconds. | |||||
Ambient Temperature Range | N/A 40 to 104°F (4 to 40°C) | N/A 40 to 104°F (4 to 40°C) | N/A 40 to 104°F (4 to 40°C). Optional: up to 130°F (55°C) with cabinet cooler | |||
Linearity | N/A ±1% of full scale (minimum 0.5 PPM) | N/A ±1% of full scale | N/A ±1% of full scale | |||
Size & Weight | N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) | N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) RACK MOUNT: 22H x 48W x 47D cm (8.7"H x 19"W x 16"D) | N/A Dimensions will vary depending on type of cabinet purge required NEMA 4: 51H x 41W x 26D cm (20"H x 16"W x 10"D) | |||
Power | N/A 115 VAC, 60 Hz 220 VAC, 50 Hz | |||||
Output Options | N/A 4-20mA into 500 ohms non-isolated standard Isolated 4-20mA, RS485 | N/A 4-20mA into 500 ohms non-isolated standard Isolated 4-20mA, RS485 outputs available | N/A 4-20mA into 500 ohms non-isolated standard Isolated 4-20mA, RS485 outputs available | |||
Alarms | N/A High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating Low flow alarm | |||||
Options | N/A Hi/Low gas, Low Flow alarms available Isolated analog, RS485 | N/A Hi/Low gas, Low Flow alarms available Isolated analog, RS485 outputs available | N/A Cabinet coolers can be fitted to most models Cabinet purge system available for use in hazardous areas Hi/Low gas, Low Flow alarms available Isolated analog, RS485 outputs available Sample conditioning systems available for removal of light moisture and/or dust | |||
Analyzer Type | N/A O2 Analyzer | |||||
Hazardous Area Rating Options | N/A Class 1, Div 1, Grp A-D Hazardous Area Rating | N/A Control Cabinet - General Purpose, Non-Hazardous Detector Cabinet - NEMA7 Class 1 Division 1 Groups BCD | N/A Class 1 Div 2 or Class 1 Div 1 Hazardous Area Ratings available | |||
|