New Call-to-action
For continuous analysis of trace PPM levels of Oxygen (O2) in process gas streams. Applications include blanketing mixtures, glove boxes, electronics, research, Hydrogen/Nitrogen mixtures, and many others.
Unit of Measure
Items
415N7MC-largepic

Model 415N7MC Trace Oxygen Analyzer, Wall Mounted NEMA7 UL/CSA Explosion-proof, Class 1 Div 1 Group BCD

RMN7 21

Model 415RMN7 Trace Oxygen Analyzer, ex-proof sensor housing with rack mount control cabinet (two separate enclosures)

Purged cabinets

Model 415 D1 or D2, Trace Oxygen Analyzer with cabinet purge systems for hazardous areas
Method of Detection N/A Customer replaceable 'fuel cell' oxygen sensor
Ranges Available N/A Any range between 0-100 PPM and 0-10000 PPM
Resolution N/A 1 PPM
Accuracy & Repeatability N/A ±1% of full scale N/A ±1% of full scale N/A ±1% of full scale
Drift N/A Less than 1% of full scale per week
Response Time (T-90) N/A In some cases, ppmO2 sensor may require an initial purge-down from air to low PPM O2 which may last 1-2 hours. After purge, T90 response O2 is less than 20 seconds.
Ambient Temperature Range N/A 40 to 104°F (4 to 40°C) N/A 40 to 104°F (4 to 40°C) N/A 40 to 104°F (4 to 40°C). Optional: up to 130°F (55°C) with cabinet cooler
Linearity N/A ±1% of full scale (minimum 0.5 PPM) N/A ±1% of full scale N/A ±1% of full scale
Size & Weight N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) RACK MOUNT: 22H x 48W x 47D cm (8.7"H x 19"W x 16"D) N/A Dimensions will vary depending on type of cabinet purge required NEMA 4: 51H x 41W x 26D cm (20"H x 16"W x 10"D)
Power N/A 115 VAC, 60 Hz 220 VAC, 50 Hz
Output Options N/A 4-20mA into 500 ohms non-isolated standard Isolated 4-20mA, RS485 N/A 4-20mA into 500 ohms non-isolated standard Isolated 4-20mA, RS485 outputs available N/A 4-20mA into 500 ohms non-isolated standard Isolated 4-20mA, RS485 outputs available
Alarms N/A High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating Low flow alarm
Options N/A Hi/Low gas, Low Flow alarms available Isolated analog, RS485 N/A Hi/Low gas, Low Flow alarms available Isolated analog, RS485 outputs available N/A Cabinet coolers can be fitted to most models Cabinet purge system available for use in hazardous areas Hi/Low gas, Low Flow alarms available Isolated analog, RS485 outputs available Sample conditioning systems available for removal of light moisture and/or dust
Analyzer Type N/A O2 Analyzer
Hazardous Area Rating Options N/A Class 1, Div 1, Grp A-D Hazardous Area Rating N/A Control Cabinet - General Purpose, Non-Hazardous Detector Cabinet - NEMA7 Class 1 Division 1 Groups BCD N/A Class 1 Div 2 or Class 1 Div 1 Hazardous Area Ratings available
View Our
Product Catalog
Have a question?
Contact Us
Ready to get started?
Request Quote