Continuous Process Trace Oxygen Gas Analyzer by Electrochemical Sensor - 415 Series
Continuous Oxygen Analyzers (O2)
Process PPM Oxygen (O2) analyzer from the Nova FLEXI-NOVA Series Platform, designed for light-duty continuous gas measurements.
Unit of Measure
Items |
/Asset/flexinovaN42.jpg Model 415N4 Model 415N4 Trace Oxygen Analyzer, Wall Mounted NEMA4 (IP65) Enclosure Rating |
/Asset/flexinovaN42.jpg Model 415N4N7 Model 415N4N7 Trace Oxygen Analyzer, , ex-proof sensor housing with NEMA4 wall-mount control cabinet (two separate enclosures) |
/Asset/415N7MC-largepic.jpg Model 415N7MC Model 415N7MC Trace Oxygen Analyzer, Wall Mounted NEMA7 UL/CSA Explosion-proof, Class 1 Div 1 Group BCD |
/Asset/RMN7-21.jpg Model 415RMN7 Model 415RMN7 Trace Oxygen Analyzer, ex-proof sensor housing with rack mount control cabinet (two separate enclosures) |
/Asset/N4-+-D1-&-D2-purge21.jpg Model 415 D1 or D2 Model 415 D1 or D2, Trace Oxygen Analyzer with cabinet purge systems for hazardous areas |
|||||
Method of Detection | N/A Customer-replaceable electrochemical ppm oxygen sensor | N/A Customer replaceable 'fuel cell' ppm oxygen sensor | N/A Customer replaceable 'fuel cell' oxygen sensor | N/A Customer replaceable 'fuel cell' oxygen sensor | N/A Customer replaceable 'fuel cell' oxygen sensor | |||||
Ranges Available | N/A Any range between 0-100 PPM and 0-10,000 PPM | N/A Any range between 0-100 PPM and 0-10,000 PPM | N/A Any range between 0-100 PPM and 0-10000 PPM | N/A Any range between 0-100 PPM and 0-10000 PPM | N/A Any range between 0-100 PPM and 0-10000 PPM | |||||
Accuracy & Repeatability | N/A ±1% of full scale | N/A ±1% of full scale | N/A ±1% of full scale | N/A ±1% of full scale | N/A ±1% of full scale | |||||
Drift | N/A Less than 1% of full scale per week | |||||||||
Ambient Temperature Range | N/A 40 to 104°F (4 to 40°C). Optional: up to 130°F (55°C) with cabinet cooler | N/A 40 to 104°F (4 to 40°C) | N/A 40 to 104°F (4 to 40°C) | N/A 40 to 104°F (4 to 40°C) | N/A 40 to 104°F (4 to 40°C). Optional: up to 130°F (55°C) with cabinet cooler | |||||
Linearity | N/A ±1% of full scale (minimum 0.5 PPM) | N/A ±1% of full scale | N/A ±1% of full scale (minimum 0.5 PPM) | N/A ±1% of full scale | N/A ±1% of full scale | |||||
Size & Weight | N/A NEMA 4: 51H x 41W x 26D cm (20"H x 16"W x 10"D) RACK MOUNT: 22H x 48W x 47D cm (8.7"H x 19"W x 16"D) | N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) NEMA 4: 51H x 41W x 26D cm (20"H x 16"W x 10"D) | N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) | N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) RACK MOUNT: 22H x 48W x 47D cm (8.7"H x 19"W x 16"D) | N/A Dimensions will vary depending on type of cabinet purge required NEMA 4: 51H x 41W x 26D cm (20"H x 16"W x 10"D) | |||||
Output Options | N/A 4-20 mA into 500 ohms non-isolated standard Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs | N/A 4-20 mA into 500 ohms non-isolated standard Isolated 4-20mA | N/A 4-20mA into 500 ohms non-isolated standard Isolated 4-20mA, RS485 | N/A 4-20mA into 500 ohms non-isolated standard Isolated 4-20mA, RS485 outputs available | N/A 4-20mA into 500 ohms non-isolated standard Isolated 4-20mA, RS485 outputs available | |||||
Alarms | N/A High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating Low flow alarm | |||||||||
Options | N/A Cabinet coolers can be fitted to most models Cabinet purge system available for use in hazardous areas Hi/Low gas, Low Flow alarms available Isolated analog, RS232, RS485, MODBUS, and Ethernet outputs available Sample conditioning systems available for removal of moisture and/or dust Sensors mounted in temperature controlled heated box to improve accuracy | N/A Cabinet coolers can be fitted to most models Cabinet purge system available for use in hazardous areas Cold weather package for operation to -20°C (-4°F) Full automatic calibration with touch screen LCD display Hi/Low gas, Low Flow, and diagnostic alarms available Isolated analog, RS232, RS485, MODBUS, and Ethernet outputs available One-step 'cal-now' button with touch screen LCD display Sample conditioning systems available for removal of moisture, acidic gas, and dust Sensors mounted in temperature controlled heated box to improve accuracy | N/A Hi/Low gas, Low Flow alarms available Isolated analog, RS485 | N/A Hi/Low gas, Low Flow alarms available Isolated analog, RS485 outputs available | N/A Cabinet coolers can be fitted to most models Cabinet purge system available for use in hazardous areas Hi/Low gas, Low Flow alarms available Isolated analog, RS485 outputs available Sample conditioning systems available for removal of light moisture and/or dust | |||||
Unique Applications |
N/A
The O2 sensor in the Model 415 is not normally affected by gas stream composition. However, continuous or frequent exposure to high levels of acid gases such as carbon dioxide (CO2) and sulfur dioxide (SO2) can cause decreased cell life. All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova at 1-800-295-3771. In many cases, we are able to build an analyzer specific to your needs. |
N/A
The O2 sensor in the Model 415 is not normally affected by gas stream composition. However, continuous or frequent exposure to high levels of acid gases such as carbon dioxide (CO2) and sulfur dioxide (SO2) can cause decreased cell life. All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova at 1-800-295-3771. In many cases, we are able to build an analyzer specific to your needs. |
N/A The O2 sensor in the Model 415 is not normally affected by gas stream composition. However, continuous or frequent exposure to high levels of acid gases such as carbon dioxide (CO2) and sulfur dioxide (SO2) can cause decreased cell life. All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova at 1-800-295-3771. In many cases, we are able to build an analyzer specific to your needs. |
N/A
The O2 sensor in the Model 415 is not normally affected by gas stream composition. However, continuous or frequent exposure to high levels of acid gases such as carbon dioxide (CO2) and sulfur dioxide (SO2) can cause decreased cell life. All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova at 1-800-295-3771. In many cases, we are able to build an analyzer specific to your needs. |
N/A
The O2 sensor in the Model 415 is not normally affected by gas stream composition. However, continuous or frequent exposure to high levels of acid gases such as carbon dioxide (CO2) and sulfur dioxide (SO2) can cause decreased cell life. All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova at 1-800-295-3771. In many cases, we are able to build an analyzer specific to your needs. |
|||||
Analyzer Type | N/A O2 Analyzer | |||||||||
Hazardous Area Rating Options | N/A General Purpose, Non-Hazardous | N/A Control Cabinet - General Purpose, Non-Hazardous Detector Cabinet - NEMA7 Class 1 Division 1 Groups BCD | N/A Class 1, Div 1, Grp A-D Hazardous Area Rating | N/A Control Cabinet - General Purpose, Non-Hazardous Detector Cabinet - NEMA7 Class 1 Division 1 Groups BCD | N/A Class 1 Div 2 or Class 1 Div 1 Hazardous Area Ratings available | |||||
|