Continuous Process Hydrogen Gas Analyzer - 430 Series
Continuous Hydrogen Analyzers for Hazardous Locations (H2)
For continuous analysis of up to 100% Hydrogen (H2) in process gas streams. Also recommended for other applications such as H2 cooled generators, electrolysis units, refinery gas, heat treating atmospheres, blast furnace gas, and many more.
Unit of Measure
Items |
/Asset/N7MC-generic.jpg Model 430N7MC Model 430N7MC Hydrogen Analyzer, Wall Mounted NEMA7 UL/CSA Explosion-proof with Non-intrusive Magnetic Calibration, Meets Class 1 Div 1 Group BCD Rating |
/Asset/RMN7-generic.jpg Model 430RMN7 Model 430RMN7, Hydrogen Analyzer, ex-proof sensor housing with rack mount control cabinet (two separate enclosures) |
/Asset/N4-+-D1-&-D2-purge21.jpg Model 430 D1 or D2 Model 430 D1 or D2, Continuous Process Hydrogen Gas Analyzer - 430 Series; NEMA 4 cabinet with Hazardous Area Purge System |
|||
Method of Detection | N/A Temperature-controlled TC cell. Expected life in excess of 10 years. Cell cannot be burned out due to loss of sample flow | |||||
Ranges Available | N/A Any range between 0-2% and 0-100% H2 | |||||
Resolution | N/A 0.1% H2 (0.01% H2 available) | |||||
Accuracy & Repeatability | N/A ±1% of full scale | |||||
Drift | N/A Less than 1% of full scale per month | |||||
Response Time (T-90) | N/A 10-15 seconds to 90% step change | |||||
Ambient Temperature Range | N/A 40 to 104°F (4 to 40°C) | N/A 32 to 122°F (0 to 50°C) | N/A 40 to 104°F (4 to 40°C). Optional: up to 130°F (55°C) with cabinet cooler | |||
Linearity | N/A ±1% of full scale | |||||
Size & Weight | N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) | N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) RACK MOUNT: 22H x 48W x 47D cm (8.7"H x 19"W x 16"D) | N/A NEMA 4: 61H x 51W x 31D cm (24"H x 20"W x 12"D) (not including purge panel & vent) | |||
Power | N/A 115 VAC, 60 Hz 220 VAC, 50 Hz | |||||
Output Options | N/A 4-20 mA into 500 ohms non-isolated standard Isolated 4-20mA, RS232, RS485, serial outputs | N/A 4-20 mA into 500 ohms non-isolated standard Isolated 4-20 mA, RS232, RS485, serial outputs | N/A 4-20 mA into 500 ohms non-isolated standard Isolated 4-20 mA, RS232, RS485 serial outputs | |||
Alarms | N/A High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating | |||||
Options | N/A Hi/Low gas, Low Flow alarms available Isolated 4-20mA, RS232, RS485, serial outputs | N/A Hi/Low gas, Low Flow alarms available Isolated 4-20 mA, RS232, RS485, serial outputs | N/A Cabinet coolers can be fitted to most models Cabinet purge system available for use in hazardous areas Hi/Low gas, Low Flow alarms available High temperature filters and probes Isolated 4-20 mA, RS232, RS485 serial outputs Light duty sample conditioning systems available for removal of moisture and/or dust | |||
Analyzer Type | N/A H2 Analyzer | |||||
Hazardous Area Rating Options | N/A Class 1, Div 1, Grp A-D Hazardous Area Rating | N/A Control Cabinet - General Purpose, Non-Hazardous Detector Cabinet - NEMA7 Class 1 Division 1 Groups BCD | N/A Class 1 Div 2 or Class 1 Div 1 Hazardous Area Ratings available | |||
|
View Our
Product Catalog
Product Catalog
Have a question?
Contact Us
Contact Us
Ready to get started?
Request Quote
Request Quote