New Call-to-action
Process Methane (CH4) analyzer from the Nova FLEXI-NOVA Series Platform, designed for light-duty continuous gas measurements.
Unit of Measure
Items
Continuous Process Gas Analyzers

Model 470N4, Methane Analyzer, Wall Mounted NEMA4 (IP65) Enclosure Rating

N4N7 cabinets

Model 470N4N7, Methane Analyzer, ex-proof sensor housing with NEMA4 wall-mount control cabinet (two separate enclosures)

N7MC generic

Model 470N7MC, Methane Analyzer, Wall Mounted NEMA7 UL/CSA Explosion-proof with Non-intrusive Magnetic Calibration, Class 1 Div 1 Group BCD

RMN7 21

Model 470RMN7, Methane Analyzer, ex-proof sensor housing with rack mount control cabinet (two separate enclosures)

Purged cabinets

Model 420 D1 or D2, Methane Analyzer, with cabinet purge systems for hazardous areas
Method of Detection N/A Single cell NDIR with no moving parts
Ranges Available N/A 0-1.00, 2.00, 5.00, 10.0, 30.0, 100.0% HC's as CH4 N/A 0-1.00, 2.00, 5.00, 10.0, 30.0, 100.0% HC's as CH4 N/A 470 - 0-1, 0-5, 0-10, 0-20, 0-30, 0-50, 0-100% HCs as CH4 N/A 0-1, 0-5, 0-10, 0-20, 0-30, 0-50, 0-100% HCs as CH4 N/A 470 - 0-1, 0-5, 0-10, 0-20, 0-30, 0-50, 0-100% HCs as CH4
Resolution N/A 0.1% CH4 on % versions
Accuracy & Repeatability N/A 1% of full scale
Drift N/A Less than 2% of full scale per month
Response Time (T-90) N/A Less than 15 seconds
Ambient Temperature Range N/A 40 to 104°F (4 to 40°C). Optional: up to 130°F (55°C) with cabinet cooler N/A 40 to 104°F (4 to 40°C) N/A 40 to 104°F (4 to 40°C) N/A 40 to 104°F (4 to 40°C) N/A 40 to 104°F (4 to 40°C). Optional: up to 130°F (55°C) with cabinet cooler
Linearity N/A ±1% of full scale
Size & Weight N/A NEMA 4: 51H x 41W x 26D cm (20"H x 16"W x 10"D) RACK MOUNT: 22H x 48W x 47D cm (8.7"H x 19"W x 16"D) N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) NEMA 4: 51H x 41W x 26D cm (20"H x 16"W x 10"D) N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) RACK MOUNT: 22H x 48W x 47D cm (8.7"H x 19"W x 16"D) N/A NEMA 4: 61H x 51W x 31D cm (24"H x 20"W x 12"D) (not including purge panel & vent)
Power N/A 115 VAC, 60 Hz 220 VAC, 50 Hz
Output Options N/A 4-20mA into 500 ohms non-isolated standard Isolated 4-20mA, RS232, RS485, serial outputs N/A 4-20 mA into 500 ohms non-isolated standard Isolated 4-20 mA, RS232, RS485, serial outputs N/A 4-20mA into 500 ohms non-isolated standard Isolated 4-20mA, RS232, RS485, serial outputs N/A 4-20mA into 500 ohms non-isolated standard Isolated 4-20mA, RS232, RS485 serial outputs N/A 4-20mA into 500 ohms non-isolated standard Isolated 4-20mA, RS232, RS485, serial outputs
Alarms N/A High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating Low flow alarm
Options N/A Cabinet coolers can be fitted to most models Hi/Low gas, Low Flow alarms available Isolated 4-20mA, RS232, RS485, serial outputs N/A Hi/Low gas, Low Flow alarms available Isolated 4-20 mA, RS232, RS485, serial outputs N/A Hi/Low gas, Low Flow alarms available Isolated 4-20 mA, RS232, RS485, serial outputs N/A Hi/Low gas, Low Flow alarms available Isolated 4-20mA, RS232, RS485 serial outputs N/A Cabinet coolers can be fitted to most models Cabinet purge system available for use in hazardous areas Hi/Low gas, Low Flow alarms available High temperature filters and probes Isolated 4-20mA, RS232, RS485, serial outputs Light duty sample conditioning systems available for removal of moisture and/or dust
Analyzer Type N/A Methane Analyzer N/A Methane Analyzer N/A Methane Analyzer N/A Methane Analyzer (HC's as CH4) N/A Methane Analyzer
Hazardous Area Rating Options N/A General Purpose, Non-Hazardous N/A Control Cabinet - General Purpose, Non-Hazardous Detector Cabinet - NEMA7 Class 1 Division 1 Groups BCD N/A Class 1, Div 1, Grp A-D Hazardous Area Rating N/A Control Cabinet - General Purpose, Non-Hazardous Detector Cabinet - NEMA7 Class 1 Division 1 Groups BCD N/A Class 1 Div 2 or Class 1 Div 1 Hazardous Area Ratings available
View Our
Product Catalog
Have a question?
Contact Us
Ready to get started?
Request Quote