New Call-to-action
Process Carbon Dioxide (CO2) analyzer from the Nova FLEXI-NOVA Series Platform, designed for light-duty continuous gas measurements.
Unit of Measure
Items
Continuous Process Gas Analyzers

Model 420N4 Carbon Dioxide Analyzer, Wall Mounted NEMA4 (IP65) Enclosure Rating

N4N7 cabinets

Model 420N4N7 Carbon Dioxide Analyzer, ex-proof sensor housing with NEMA4 wall-mount control cabinet (two separate enclosures)

N7MC generic

Model 420N7MC Carbon Dioxide Analyzer, in Explosion-proof cabinet, Class 1 Div 1 Group BCD

RMN7 21

Model 420RMN7 Carbon Dioxide Analyzer, ex-proof sensor housing with rack mount control cabinet (two separate enclosures)

Purged cabinets

Model 420 D1 or D2 Carbon Dioxide Analyzer, with cabinet purge systems for hazardous areas
Method of Detection N/A Single cell NDIR with no moving parts
Ranges Available N/A 420 - 0-1, 0-5, 0-10, 0-20, 0-30, 0-50, 0-100% CO2 420L - 0-5,000 PPM CO2 420L-LP - 0-500, 1000, 2000, 5000, 10000 PPM (may be available, check with NOVA) N/A 420 - 0-1, 0-5, 0-10, 0-20, 0-30, 0-50, 0-100% CO2 420L - 0-5,000 PPM CO2 N/A 420 - 0-1, 0-5, 0-10, 0-20, 0-30, 0-50, 0-100% CO2 420L - 0-5,000 PPM CO2 N/A 420 - 0-1, 0-5, 0-10, 0-20, 0-30, 0-50, 0-100% CO2 420L - 0-5,000 PPM CO2 N/A 420 - 0-1, 0-5, 0-10, 0-20, 0-30, 0-50, 0-100% CO2 420L - 0-5,000 PPM CO2 420L-LP - 0-500, 1000, 2000, 5000, 10000 PPM (may be available, check with NOVA)
Accuracy & Repeatability N/A ±1-3% of full scale, depending on measurement range and application
Drift N/A Usually 2% of full scale per month or less, depending on range and application
Response Time (T-90) N/A Usually 20-30 seconds to 90% step change, depending on range and application
Ambient Temperature Range N/A 40 to 104°F (4 to 40°C). Optional: up to 130°F (55°C) with cabinet cooler N/A 40 to 104°F (4 to 40°C). N/A 40 to 104°F (4 to 40°C). Optional: up to 130°F (55°C) with cabinet cooler N/A 40 to 104°F (4 to 40°C) N/A 40 to 104°F (4 to 40°C). Optional: up to 130°F (55°C) with cabinet cooler
Linearity N/A Usually ±1.5% of full scale, depending on range and application N/A Usually ±1.5% of full scale, depending on range and application N/A Usually ±1.5% of full scale, depending on range and application N/A Usually ±1.5% of full scale, depending on gas measured N/A Usually ±1.5% of full scale, depending on gas measured
Size & Weight N/A NEMA 4: 51H x 41W x 26D cm (20"H x 16"W x 10"D) RACK MOUNT: 22H x 48W x 47D cm (8.7"H x 19"W x 16"D) N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) NEMA 4: 51H x 41W x 26D cm (20"H x 16"W x 10"D) N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) RACK MOUNT: 22H x 48W x 47D cm (8.7"H x 19"W x 16"D) N/A NEMA 4: 61H x 51W x 31D cm (24"H x 20"W x 12"D) (not including purge panel & vent)
Power N/A 115 VAC, 60 Hz 220 VAC, 50 Hz
Alarms N/A High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating Low flow alarm
Options N/A Cabinet coolers can be fitted to most models Hi/Low gas, Low Flow alarms available High temperature filters and probes Light duty sample conditioning systems available for removal of moisture and dust N/A Hi/Low gas, Low Flow alarms available High temperature filters and probes N/A Cabinet coolers can be fitted to most models Cabinet purge system available for use in hazardous areas Cold weather package for operation to -5°F (-20°C) Full automatic calibration with touch screen LCD display Hi/Low gas, Low Flow, and diagnostic alarms available High temperature filters and probes Isolated analog, RS232, RS485, MODBUS, and Ethernet outputs available One-step 'cal-now' button with touch screen LCD display Sample conditioning systems available for removal of moisture, acidic gas, and dust Sensor mounted in temperature controlled heated box to improve accuracy N/A Hi/Low gas, Low Flow, alarms available High temperature filters and probes N/A Cabinet coolers can be fitted to most models Cabinet purge system available for use in hazardous areas Hi/Low gas, Low Flow, alarms available High temperature filters and probes Light duty sample conditioning systems available for removal of moisture and dust
Analyzer Type N/A CO2 Gas Analyzer
Hazardous Area Rating Options N/A General Purpose, Non-Hazardous N/A Control Cabinet - General Purpose, Non-Hazardous Detector Cabinet - NEMA7 Class 1 Division 1 Groups BCD N/A Class 1, Div 1, Grp A-D Hazardous Area Rating N/A Control Cabinet - General Purpose, Non-Hazardous Detector Cabinet - NEMA7 Class 1 Division 1 Groups BCD N/A Class 1 Div 2 or Class 1 Div 1 Hazardous Area Ratings available
View Our
Product Catalog
Have a question?
Contact Us
Ready to get started?
Request Quote