Continuous Process Carbon Dioxide Analyzer by Infrared Detector - 420 Series
Continuous Carbon Dioxide Analyzers for Hazardous Locations (CO2)
For continuous analysis of Carbon Dioxide (CO2) in process gas streams using an infrared detector. Percent and PPM levels available as Models 420 & 420L respectively.
Unit of Measure
Items |
/Asset/N7MC-generic.jpg Model 420N7MC Model 420N7MC Carbon Dioxide Analyzer, in Explosion-proof cabinet, Class 1 Div 1 Group BCD |
/Asset/RMN7-21.jpg Model 420RMN7 Model 420RMN7 Carbon Dioxide Analyzer, ex-proof sensor housing with rack mount control cabinet (two separate enclosures) |
/Asset/N4-+-D1-&-D2-purge21.jpg Model 420 D1 or D2 Model 420 D1 or D2 Carbon Dioxide Analyzer, with cabinet purge systems for hazardous areas |
|||
Method of Detection | N/A Single cell NDIR with no moving parts | |||||
Ranges Available | N/A 420 - 0-1, 0-5, 0-10, 0-20, 0-30, 0-50, 0-100% CO2 420L - 0-5,000 PPM CO2 | N/A 420 - 0-1, 0-5, 0-10, 0-20, 0-30, 0-50, 0-100% CO2 420L - 0-5,000 PPM CO2 | N/A 420 - 0-1, 0-5, 0-10, 0-20, 0-30, 0-50, 0-100% CO2 420L - 0-5,000 PPM CO2 420L-LP - 0-500, 1000, 2000, 5000, 10000 PPM (may be available, check with NOVA) | |||
Resolution | N/A 0.1% CO2 on % versions, 1 PPM CO2 on PPM versions | N/A 1 or 10ppm on most ppm ranges; 0.1% on most % ranges | N/A 1 or 10ppm on most ppm ranges; 0.1% on most % ranges | |||
Accuracy & Repeatability | N/A ±1-3% of full scale, depending on measurement range and application | |||||
Drift | N/A Usually 2% of full scale per month or less, depending on range and application | |||||
Response Time (T-90) | N/A Usually 20-30 seconds to 90% step change, depending on range and application | |||||
Ambient Temperature Range | N/A 40 to 104°F (4 to 40°C). Optional: up to 130°F (55°C) with cabinet cooler | N/A 40 to 104°F (4 to 40°C) | N/A 40 to 104°F (4 to 40°C). Optional: up to 130°F (55°C) with cabinet cooler | |||
Linearity | N/A Usually ±1.5% of full scale, depending on range and application | N/A Usually ±1.5% of full scale, depending on gas measured | N/A Usually ±1.5% of full scale, depending on gas measured | |||
Size & Weight | N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) | N/A EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) RACK MOUNT: 22H x 48W x 47D cm (8.7"H x 19"W x 16"D) | N/A NEMA 4: 61H x 51W x 31D cm (24"H x 20"W x 12"D) (not including purge panel & vent) | |||
Power | N/A 115 VAC, 60 Hz 220 VAC, 50 Hz | |||||
Output Options | N/A 4-20 mA into 500 ohms non-isolated standard Isolated 4-20 mA, RS232, RS485, USB serial outputs | |||||
Alarms | N/A High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating Low flow alarm | |||||
Options | N/A Cabinet coolers can be fitted to most models Cabinet purge system available for use in hazardous areas Cold weather package for operation to -5°F (-20°C) Full automatic calibration with touch screen LCD display Hi/Low gas, Low Flow, and diagnostic alarms available High temperature filters and probes Isolated analog, RS232, RS485, MODBUS, and Ethernet outputs available One-step 'cal-now' button with touch screen LCD display Sample conditioning systems available for removal of moisture, acidic gas, and dust Sensor mounted in temperature controlled heated box to improve accuracy | N/A Hi/Low gas, Low Flow, alarms available High temperature filters and probes | N/A Cabinet coolers can be fitted to most models Cabinet purge system available for use in hazardous areas Hi/Low gas, Low Flow, alarms available High temperature filters and probes Light duty sample conditioning systems available for removal of moisture and dust | |||
Analyzer Type | N/A CO2 Gas Analyzer | |||||
Hazardous Area Rating Options | N/A Class 1, Div 1, Grp A-D Hazardous Area Rating | N/A Control Cabinet - General Purpose, Non-Hazardous Detector Cabinet - NEMA7 Class 1 Division 1 Groups BCD | N/A Class 1 Div 2 or Class 1 Div 1 Hazardous Area Ratings available | |||
|
View Our
Product Catalog
Product Catalog
Have a question?
Contact Us
Contact Us
Ready to get started?
Request Quote