All Categories > By Primary Gas to be Measured > Carbon Monoxide Analyzers (CO) > Continuous Carbon Monoxide Analyzers (Continuous CO Analyzers) > Continuous Process Carbon Monoxide Gas Analyzer by Infrared Detector - 481 Series > View Items  
Download PDF Download PDF     Printable Page     Email Email This Page     Save To Favorites Save To Favorites

Continuous Process Carbon Monoxide Gas Analyzer by Infrared Detector - 481 Series

Check up to five results to perform an action.


For continuous analysis of Carbon Monoxide (CO) in process gas streams using an infrared detector. Percent and PPM levels available as Models 481 and 481L respectively.


Search Items


Compare Items
   
  Results 1 - 7 of 7 1 

Item #

Enclosure and Mounting Details

Resolution

Power

Analyzer Type

Hazardous Area Rating Options

Model 481LN4 Continuous Process Analyzer for PPM Carbon Monoxide by Infrared Detector 0.1% CO on % versions, 1 PPM CO on PPM versions 115 VAC, 60 Hz
220 VAC, 50 Hz
CO Analyzer N/A
Model 481N4 Continuous Process Analyzer for Carbon Monoxide by Infrared Detector, Wall Mounted NEMA4 (IP65) Enclosure Rating 0.1% CO on % versions, 1 PPM CO on PPM versions 115 VAC, 60 Hz
220 VAC, 50 Hz
CO Analyzer General Purpose, Non-Hazardous
Model 481N4X Continuous Process Analyzer for Carbon Monoxide by Infrared Detector, Wall Mounted Corrosion-resistant NEMA4X (IP65) Enclosure Rating 0.1% CO on % versions, 1 PPM CO on PPM versions 115 VAC, 60 Hz
220 VAC, 50 Hz
CO Analyzer General Purpose, Non-Hazardous
Model 481RM Continuous Process Analyzer for Carbon Monoxide by Infrared Detector, 19" (483mm) Rack Mounted, on Sliding Rails 0.1% CO on % versions, 1 PPM CO on PPM versions 115 VAC, 60 Hz
220 VAC, 50 Hz
CO Analyzer General Purpose, Non-Hazardous
Model 481N7MC Continuous Process Analyzer for Carbon Monoxide by Infrared Detector, Wall Mounted NEMA7 UL/CSA Explosion-proof with Non-intrusive Magnetic Calibration, Class 1 Div 1 Group BCD 0.1% CO on % versions, 1 PPM CO on PPM versions 115 VAC, 60 Hz
220 VAC, 50 Hz
CO Analyzer Class 1, Div 1, Grp A-D Hazardous Area Rating
Model 481RMN7 Continuous Process Analyzer for Carbon Monoxide by Infrared Detector, ex-proof sensor housing with rack mount control cabinet (two separate enclosures) 0.1% CO on % versions, 1 PPM CO on PPM versions 115 VAC, 60 Hz
220 VAC, 50 Hz
CO Analyzer Class 1, Div 1, Grp A-D Hazardous Area Rating
Model 481D2 Continuous Process Carbon Monoxide Gas Analyzer by Infrared Detector - 481 Series; NEMA 4 cabinet with Hazardous Area Purge System 0.1% CO on % versions, 1 PPM CO on PPM versions 115 VAC, 60 Hz
220 VAC, 50 Hz
CO Analyzer Class 1, Div 2 Hazardous Area Rating
  Results 1 - 7 of 7 1