New Call-to-action
For continuous analysis of trace PPM levels of Oxygen (O2) in process gas streams. Applications include blanketing mixtures, glove boxes, electronics, research, Hydrogen/Nitrogen mixtures, and many others.
1 - 6 of 6 | Results Per Page | View | Unit of Measure
1 

Item #

Enclosure and Mounting Details

Resolution

Response Time (T-90)

Power

Analyzer Type

Hazardous Area Rating Options

Model 415N4 N/A Process Analyzer for Trace Oxygen by Electrochemical Sensor, Wall Mounted NEMA4 (IP65) Enclosure Rating N/A ±1 PPM N/A O2 sensor may require an initial purge down from air to low PPM O2 which may last up to 6 hours. After purge, T90 response from 1000 to 0 PPM O2 is 30 seconds. N/A 115 VAC, 60 Hz 220 VAC, 50 Hz N/A O2 Analyzer N/A General Purpose, Non-Hazardous
Model 415N4X N/A Process Analyzer for Trace Oxygen by Electrochemical Sensor, Wall Mounted Corrosion-resistant NEMA4X (IP65) Enclosure Rating N/A ±1 PPM N/A O2 sensor may require an initial purge down from air to low PPM O2 which may last up to 6 hours. After purge, T90 response from 1000 to 0 PPM O2 is 30 seconds. N/A 115 VAC, 60 Hz 220 VAC, 50 Hz N/A O2 Analyzer N/A General Purpose, Non-Hazardous
Model 415RM N/A Process Analyzer for Trace Oxygen by Electrochemical Sensor, 19" (483mm) Rack Mounted, on Sliding Rails N/A ±1 PPM N/A O2 sensor may require an initial purge down from air to low PPM O2 which may last up to 6 hours. After purge, T90 response from 1000 to 0 PPM O2 is 30 seconds. N/A 115 VAC, 60 Hz 220 VAC, 50 Hz N/A O2 Analyzer N/A General Purpose, Non-Hazardous
Model 415N7MC N/A Process Analyzer for Trace Oxygen by Electrochemical Sensor, Wall Mounted NEMA7 UL/CSA Explosion-proof with Non-intrusive Magnetic Calibration, Class 1 Div 1 Group BCD N/A ±1 PPM N/A O2 sensor may require an initial purge down from air to low PPM O2 which may last up to 6 hours. After purge, T90 response from 1000 to 0 PPM O2 is 30 seconds. N/A 115 VAC, 60 Hz 220 VAC, 50 Hz N/A O2 Analyzer N/A Class 1, Div 1, Grp A-D Hazardous Area Rating
Model 415RMN7 N/A Process Analyzer for Trace Oxygen by Electrochemical Sensor, ex-proof sensor housing with rack mount control cabinet (two separate enclosures) N/A ±1 PPM N/A O2 sensor may require an initial purge down from air to low PPM O2 which may last up to 6 hours. After purge, T90 response from 1000 to 0 PPM O2 is 30 seconds. N/A 115 VAC, 60 Hz 220 VAC, 50 Hz N/A O2 Analyzer N/A Class 1, Div 1, Grp A-D Hazardous Area Rating
Model 415D2 N/A Model 415 with NEMA 4 cabinet with Hazardous Area Purge System; available for Class 1 Div1 & Div2 hazardous areas N/A ±1 PPM N/A O2 sensor may require an initial purge down from air to low PPM O2 which may last up to 6 hours. After purge, T90 response from 1000 to 0 PPM O2 is 30 seconds. N/A 115 VAC, 60 Hz 220 VAC, 50 Hz N/A O2 Analyzer N/A Class 1, Div 2 Hazardous Area Rating