New Call-to-action
For continuous analysis of many binary gas mixtures comprised of H2, CO2, O2, CH4, SO2, Ar, He, NH3, SF6, air, and others. Applications include heat treating atmospheres, welding gas mixtures, blanketing gas mixtures, Ammonia synthesis, leak detection, purge monitoring, flue gas, magnesium blanketing by SF6 and others.
1 - 6 of 6 | Results Per Page | View | Unit of Measure
1 

Item #

Enclosure and Mounting Details

Resolution

Response Time (T-90)

Power

Analyzer Type

Hazardous Area Rating Options

Model 425N4 N/A Continuous Process Analyzer for Binary Gas Mixtures by Thermal Conductivity, Wall Mounted NEMA4 (IP65) Enclosure Rating N/A 0.1% of gas to be measured N/A 10-15 seconds to 90% step change N/A 115 VAC, 60 Hz 220 VAC, 50 Hz N/A Binary Gas Analyzer N/A General Purpose, Non-Hazardous
Model 425N4X N/A Continuous Process Analyzer for Binary Gas Mixtures by Thermal Conductivity, Wall Mounted Corrosion-resistant NEMA4X (IP65) Enclosure Rating N/A 0.1% of gas to be measured N/A 10-15 seconds to 90% step change N/A 115 VAC, 60 Hz 220 VAC, 50 Hz N/A Binary Gas Analyzer N/A General Purpose, Non-Hazardous
Model 425RM N/A Continuous Process Analyzer for Binary Gas Mixtures by Thermal Conductivity, 19" (483mm) Rack Mounted, on Sliding Rails N/A 0.1% of gas to be measured N/A 10-15 seconds to 90% step change N/A 115 VAC, 60 Hz 220 VAC, 50 Hz N/A Binary Gas Analyzer N/A General Purpose, Non-Hazardous
Model 425N7MC N/A Continuous Process Analyzer for Binary Gas Mixtures by Thermal Conductivity, Wall Mounted NEMA7 UL/CSA Explosion-proof with Non-intrusive Magnetic Calibration, Class 1 Div 1 Group BCD N/A 0.1% of gas to be measured N/A 10-15 seconds to 90% step change N/A 115 VAC, 60 Hz 220 VAC, 50 Hz N/A Binary Gas Analyzer N/A Class 1, Div 1, Grp A-D Hazardous Area Rating
Model 425RMN7 N/A Continuous Process Analyzer for Binary Gas Mixtures by Thermal Conductivity, ex-proof sensor housing with rack mount control cabinet (two separate enclosures) N/A 0.1% of gas to be measured N/A 10-15 seconds to 90% step change N/A 115 VAC, 60 Hz 220 VAC, 50 Hz N/A Binary Gas Analyzer N/A Class 1, Div 1, Grp A-D Hazardous Area Rating
Model 425D2 N/A Continuous Process Analyzer for Binary Gas Mixtures by Thermal Conductivity - 425 Series; NEMA 4 cabinet with Hazardous Area Purge System N/A 0.1% of gas to be measured N/A 10-15 seconds to 90% step change N/A 115 VAC, 60 Hz 220 VAC, 50 Hz N/A Binary Gas Analyzer N/A Class 1, Div 2 Hazardous Area Rating
1 - 6 of 6 | Results Per Page | View | Unit of Measure