970 Series Syngas
Multigas Continuous Carbon Monoxide Analyzers for Hazardous Locations (Multigas Continuous CO Analyzers)
For continuous monitoring of syngas and gasification atmospheres or other industrial process gases for any combination of methane (CH4), carbon dioxide (CO2), carbon monoxide (CO) and hydrogen (H2) and oxygen (O 2).
Item # |
Method of Detection |
Ranges Available |
Resolution |
Alarms |
---|---|---|---|---|
975A | Method of Detection N/A Electrochemical sensor for O2 NDIR infrared detector for CO, CO2 and CH4 Thermal conductivity cell for H2 | Ranges Available N/A 0-10.0%, 0-50.0%, 0-100.0% CO 0-10.0%, 0-50.0%, 0-100.0% CO2 0-2.0%, 0-25.0%, 0-50.0%, 0-100.0% O2 0-5.0%, 0-50.0%, 0-100.0% H2 0-50.0%, 0-100.0% CH4 | Resolution N/A 0.1% for all gases | Alarms N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
972A | Method of Detection N/A NDIR infrared detector for CO and CO2 | Ranges Available N/A 0-2.0%, 0-50.0%, 0-100.0% CO 0-2.0%, 0-50.0%, 0-100.0% CO2 | Resolution N/A 0.1% for all gases | Alarms N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
974B | Method of Detection N/A NDIR infrared detector for CO and CO2 Paramagnetic sensor for O2 Thermal conductivity cell for H2 | Ranges Available N/A 0-2.0%, 0-25.0%, 0-50.0%, 0-100.0% O2 0-2.0%, 0-50.0%, 0-100.0% CO 0-2.0%, 0-50.0%, 0-100.0% CO2 0-2.0%, 0-50.0%, 0-100.0% H2 | Resolution N/A 0.1% for all gases | Alarms N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
974A | Method of Detection N/A NDIR infrared detector for CO, CO2 and CH4 Paramagnetic sensor for O2 | Ranges Available N/A 0-2.0%, 0-25.0%, 0-50.0%, 0-100.0% O2 0-2.0%, 0-50.0%, 0-100.0% CH4 0-2.0%, 0-50.0%, 0-100.0% CO 0-2.0%, 0-50.0%, 0-100.0% CO2 | Resolution N/A 0.1% for all gases | Alarms N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
974C | Method of Detection N/A NDIR infrared detector for CO, CO2 and CH4 Thermal conductivity cell for H2 | Ranges Available N/A 0-2.0%, 0-50.0%, 0-100.0% CH4 0-2.0%, 0-50.0%, 0-100.0% CO 0-2.0%, 0-50.0%, 0-100.0% CO2 0-2.0%, 0-50.0%, 0-100.0% H2 | Resolution N/A 0.1% for all gases | Alarms N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
974D | Method of Detection N/A NDIR infrared detector for CO and CH4 Paramagnetic sensor for O2 Thermal conductivity cell for H2 | Ranges Available N/A 0-2.0%, 0-25.0%, 0-50.0%, 0-100.0% O2 0-2.0%, 0-50.0%, 0-100.0% CH4 0-2.0%, 0-50.0%, 0-100.0% CO 0-2.0%, 0-50.0%, 0-100.0% H2 | Resolution N/A 0.1% for all gases | Alarms N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
973A | Method of Detection N/A NDIR infrared detector for CO, CO2 and CH4 | Ranges Available N/A 0-2.0%, 0-50.0%, 0-100.0% CH4 0-2.0%, 0-50.0%, 0-100.0% CO 0-2.0%, 0-50.0%, 0-100.0% CO2 | Resolution N/A 0.1% for all gases | Alarms N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
973B | Method of Detection N/A NDIR infrared detector for CO and CO2 Thermal conductivity cell for H2 | Ranges Available N/A 0-2.0%, 0-50.0%, 0-100.0% CO 0-2.0%, 0-50.0%, 0-100.0% CO2 0-2.0%, 0-50.0%, 0-100.0% H2 | Resolution N/A 0.1% for all gases | Alarms N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
973C | Method of Detection N/A NDIR infrared detector for CO and CO2 Paramagnetic sensor for O2 | Ranges Available N/A 0-2.0%, 0-25.0%, 0-50.0%, 0-100.0% O2 0-2.0%, 0-50.0%, 0-100.0% CO 0-2.0%, 0-50.0%, 0-100.0% CO2 | Resolution N/A 0.1% for all gases | Alarms N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
973D | Method of Detection N/A NDIR infrared detector for CO and CH4 Paramagnetic sensor for O2 | Ranges Available N/A 0-2.0%, 0-25.0%, 0-50.0%, 0-100.0% O2 0-2.0%, 0-50.0%, 0-100.0% CH4 0-2.0%, 0-50.0%, 0-100.0% CO | Resolution N/A 0.1% for all gases | Alarms N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
972E | Method of Detection N/A Paramagnetic sensor for O2 Thermal conductivity cell for H2 | Ranges Available N/A 0-2.0%, 0-25.0%, 0-50.0%, 0-100.0% O2 0-2.0%, 0-50.0%, 0-100.0% H2 | Resolution N/A 0.1% for all gases | Alarms N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
972B | Method of Detection N/A NDIR infrared detector for CO Thermal conductivity cell for H2 | Ranges Available N/A 0-2.0%, 0-50.0%, 0-100.0% CO 0-2.0%, 0-50.0%, 0-100.0% H2 | Resolution N/A 0.1% for all gases | Alarms N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
972C | Method of Detection N/A NDIR infrared detector for CO Paramagnetic sensor for O2 | Ranges Available N/A 0-2.0%, 0-25.0%, 0-50.0%, 0-100.0% O2 0-2.0%, 0-50.0%, 0-100.0% CO 0-2.0%, 0-50.0%, 0-100.0% CO2 | Resolution N/A 0.1% for all gases | Alarms N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
972D | Method of Detection N/A NDIR infrared detector for CO2 Paramagnetic sensor for O2 | Ranges Available N/A 0-2.0%, 0-25.0%, 0-50.0%, 0-100.0% O2 0-2.0%, 0-50.0%, 0-100.0% CO2 | Resolution N/A 0.1% for all gases | Alarms N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
972E | Method of Detection N/A Paramagnetic sensor for O2 Thermal conductivity cell for H2 | Ranges Available N/A 0-2.0%, 0-25.0%, 0-50.0%, 0-100.0% O2 0-2.0%, 0-50.0%, 0-100.0% H2 | Resolution N/A 0.1% for all gases | Alarms N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
972F | Method of Detection N/A NDIR infrared detector for CH4 Paramagnetic sensor for O2 | Ranges Available N/A 0-2.0%, 0-25.0%, 0-50.0%, 0-100.0% O2 0-2.0%, 0-50.0%, 0-100.0% CH4 | Resolution N/A 0.1% for all gases | Alarms N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
972G | Method of Detection N/A NDIR infrared detector for CO2 Thermal conductivity cell for H2 | Ranges Available N/A 0-2.0%, 0-50.0%, 0-100.0% CO2 0-2.0%, 0-50.0%, 0-100.0% H2 | Resolution N/A 0.1% for all gases | Alarms N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
971A | Method of Detection N/A NDIR infrared detector for CO | Ranges Available N/A 0-2.0%, 0-50.0%, 0-100.0% CO | Resolution N/A 0.1% for all gases | Alarms N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
971B | Method of Detection N/A Thermal conductivity cell for H2 | Ranges Available N/A 0-2.0%, 0-50.0%, 0-100.0% H2 | Resolution N/A 0.1% for all gases | Alarms N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
971D | Method of Detection N/A NDIR infrared detector for CH4 | Ranges Available N/A 0-2.0%, 0-50.0%, 0-100.0% CH4 | Resolution N/A 0.1% for all gases | Alarms N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
971E | Method of Detection N/A NDIR infrared detector for CO2 | Ranges Available N/A 0-2.0%, 0-50.0%, 0-100.0% CO2 | Resolution N/A 0.1% for all gases | Alarms N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
971F | Method of Detection N/A Paramagnetic sensor for O2 | Ranges Available N/A 0-2.0%, 0-25.0%, 0-50.0%, 0-100.0% O2 | Resolution N/A 0.1% for all gases | Alarms N/A High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating. |
View Our
Product Catalog
Product Catalog
Have a question?
Contact Us
Contact Us
Ready to get started?
Request Quote
Request Quote