Canada
270 Sherman Avenue N. Hamilton, ON L8L 6N5
Phone: (905) 545 2003• Fax: (905) 545 4248 |
United States
1925 Pine Avenue Niagara Falls, NY 14301
Phone: (716) 285-0418 • Fax: (716) 282-2937 |
|
Email: sales@nova-gas.com or websales@nova-gas.com
|
|
|
|
|
Item # 974B, Continuous Analyzer for Syn-Gas Atmospheres - O2, CO, CO2 and H2
|
|
|
|
The Nova 970 Series Syn-Gas Analyzer System has been designed with the flexibility and robustness required in the experimental and developmental environments that characterize syn-gas applications.
The Nova 970 Series utilizes high-stability infrared detectors for the simultaneous measurement of CO, CO2, and CH4. In addition, the analyzer can also be supplied with a non-consumable, long-life thermal conductivity cell for H2 that compensates for the interference effects of CO, CO2, and CH4. This ensures that H2 will always read correctly regardless of the background gas composition. A non-depleting paramagnetic sensor is used for O2 analysis. All sensors/detectors are temperature-controlled or temperature-compensated for maximum analytical stability. Auto calibration functionality allows easy calibration without user intervention. The included Serial Output Package allows connection of analyzer to personal computers via a choice of USB/RS-232/RS-485. Data recording software is also included.
|
|
|
|
|
Method of Detection
|
|
NDIR infrared detector for CO and CO2 Paramagnetic sensor for O2 Thermal conductivity cell for H2
|
|
Ranges Available
|
|
0-2.0%, 0-25.0%, 0-50.0%, 0-100.0% O2 0-2.0%, 0-50.0%, 0-100.0% CO 0-2.0%, 0-50.0%, 0-100.0% CO2 0-2.0%, 0-50.0%, 0-100.0% H2
|
|
Resolution
|
|
0.1% for all gases
|
|
Accuracy & Repeatability
|
|
± 1.5% of full scale on all gases
|
|
Drift
|
|
Less than 2% of full scale per month
|
|
Response Time (T-90)
|
|
20-30 seconds to 90% step change
|
|
Ambient Temperature Range
|
|
40-104 °F (4 to 40°C). Optional -22 to 158 °F (-30 to 70 °C) with Outdoor Packages
|
|
Linearity
|
|
± 1.5% of full scale
|
|
Size & Weight
|
|
24" H x 24" W x 10" D @ 90 lbs (61 x 61 x 25 cm @ 20 kg)
|
|
Power
|
|
115 VAC 60 Hz (220 VAC 50 Hz available)
|
|
Output Options
|
|
Isolated 4-20 mA standard RS232, RS485, MODBUS®, Ethernet outputs optional
|
|
Alarms
|
|
High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating.
|
|
|
|
|
For continuous monitoring of any combination of gases such as oxygen (O2), methane (CH4), carbon dioxide (CO2), carbon monoxide (CO) and hydrogen (H2) for experimental, developmental and industrial processes including syn-gas atmospheres.
|
|
|
|
Sensitive infrared detectors for CO, CO2 and CH4Thermal conductivity cell for H2Non-depleting paramagnetic oxygen sensorSensors/detectors temperature controlled or compensated for maximum analytical stabilityH2 reading is compensated for the interference effects of the other gases measuredHigh ranges on each channel availableTouch-screen display for gas readingsBuilt-in sample pump or pressure regulatorAutomatic calibration & serial output packageIsolated 4-20 mA analog recorder outputsDurable internal lines & sample componentsAutomatic moisture removal system included
|
|
|
|
Calculations performed on gas readings such as gas ratios and heating value of flammable gasesHi/Low gas, low flow and other alarms availableSample conditioning systems available for acidic gas and dustCabinet purge system available for use in hazardous areasOutdoor packages available for operation from -22 to 158 °F (-30 to 70 °C)Cabinet coolers can be fitted to most modelsHeated filters and high temperature probes
|
|
|
|
Ambient air for O2 and to zero all other gasesAnalyzed calibration gas with representative concentrations for span of all other gases
|
|
|
|
|
|
|
|
|
|
|
|
|
|