All Categories > By Primary Gas to be Measured > Oxygen Analyzers (O2) > Continuous Oxygen Analyzers for Hazardous Locations (O2) > Continuous Process Oxygen Gas Analyzer - 410 Series > Item # Model 410RMN7  


Item # Model 410RMN7, Model 410RMN7 Process Oxygen Analyzer, ex-proof sensor housing with rack mount control cabinet (two separate enclosures)


The Nova 410 Series represent Nova's best value in continuous process O2 analysis. This analyzer utilizes a long-life electrochemical 'fuel cell' sensor for the detection of Oxygen in process gases. The sensor produces a small millivoltage output which is directly proportional to the Oxygen detected. The output is then amplified and displayed on a digital readout meter and can also be sent to an optional recorder output. The 410 can be supplied with sampling pump or pressure regulator to suit most applications.

Cabinets: Wall Mounted NEMA7 UL/CSA Explosion-proof sensor cabinet with 19" rack mount control cabinet (two separate cabinets)






Specifications  · Applications  · Features  · Options  · Calibration

Specifications

Method of Detection

Customer replaceable electrochemical 'fuel cell' O2 sensor. Expected life 3 to 5 years depending on typical measurement concentrations.

Ranges Available

Any range from 0-2.0% to 0-100.0% O2

Resolution

0.1% O2

Accuracy & Repeatability

Below 30% O2 ±1% of full scale; above 30% O2 ±2% of full scale

Drift

Less than 2% of full scale per month

Response Time (T-90)

6-8 seconds to 90% step change

Ambient Temperature Range

32 to 122°F (0 to 50°C), Lower temperatures (-5°F, -20°C) with Cold Weather Package

Linearity

Below 30% O2 ±1% of full scale; above 30% O2 ±2% of full scale

Size & Weight

EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D)
RACK MOUNT: 22H x 48W x 47D cm (8.7"H x 19"W x 16"D)

Power

115 VAC, 60 Hz
220 VAC, 50 Hz

Output Options

4-20 mA into 500 ohms non-isolated standard
Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs

Alarms

High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating
Low flow alarm

Analyzer Type

O2 Analyzer

Primary Gas(es) to be Measured

Oxygen (O2)

Hazardous Area Rating Options

Control Cabinet - General Purpose, Non-Hazardous
Detector Cabinet - NEMA7 Class 1 Division 1 Groups BCD


Applications
      For continuous analysis of oxygen (O2) in process gas streams. Also recommended for other applications such as O2 enrichment of combustion air, flue gas analysis, oxygen deficiency analysis, and many more.




Features
  • Best value continuous O2 analyzer
  • Bright digital readout
  • Long life electrochemical O2 sensor
  • Fast response (T90 - 6 to 8 seconds)
  • Microprocessor control for push button calibration
  • Easy-to-maintain modular layout
  • Built in sample pump or pressure regulator
  • 4-20mA outputs




Options
  • Hi/Low gas, low flow, and diagnostic alarms available
  • Isolated analog, RS232, RS485, MODBUS, and Ethernet outputs available
  • Sensors mounted in temperature controlled heated box to improve accuracy
  • High temperature filters and probes




Calibration
  • Nitrogen for zero
  • Air or analyzed calibration gas for span





Print Back