Canada
270 Sherman Avenue N. Hamilton, ON L8L 6N5
Phone: (905) 545 2003• Fax: (905) 545 4248 |
United States
1925 Pine Avenue Niagara Falls, NY 14301
Phone: (716) 285-0418 • Fax: (716) 282-2937 |
|
Email: sales@nova-gas.com or websales@nova-gas.com
|
|
|
|
|
Item # Model 410RMN7, Model 410RMN7 Process Oxygen Analyzer, ex-proof sensor housing with rack mount control cabinet (two separate enclosures)
|
|
|
|
The Nova 410 Series represent Nova's best value in continuous process O2 analysis. This analyzer utilizes a long-life electrochemical 'fuel cell' sensor for the detection of Oxygen in process gases. The sensor produces a small millivoltage output which is directly proportional to the Oxygen detected. The output is then amplified and displayed on a digital readout meter and can also be sent to an optional recorder output. The 410 can be supplied with sampling pump or pressure regulator to suit most applications.
Cabinets: Wall Mounted NEMA7 UL/CSA Explosion-proof sensor cabinet with 19" rack mount control cabinet (two separate cabinets)
|
|
|
|
|
Method of Detection
|
|
Customer replaceable electrochemical 'fuel cell' O2 sensor. Expected life 3 to 5 years depending on typical measurement concentrations.
|
|
Ranges Available
|
|
Any range from 0-2.0% to 0-100.0% O2
|
|
Resolution
|
|
0.1% O2
|
|
Accuracy & Repeatability
|
|
Below 30% O2 ±1% of full scale; above 30% O2 ±2% of full scale
|
|
Drift
|
|
Less than 2% of full scale per month
|
|
Response Time (T-90)
|
|
6-8 seconds to 90% step change
|
|
Ambient Temperature Range
|
|
32 to 122°F (0 to 50°C), Lower temperatures (-5°F, -20°C) with Cold Weather Package
|
|
Linearity
|
|
Below 30% O2 ±1% of full scale; above 30% O2 ±2% of full scale
|
|
Size & Weight
|
|
EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) RACK MOUNT: 22H x 48W x 47D cm (8.7"H x 19"W x 16"D)
|
|
Power
|
|
115 VAC, 60 Hz 220 VAC, 50 Hz
|
|
Output Options
|
|
4-20 mA into 500 ohms non-isolated standard Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs
|
|
Alarms
|
|
High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating Low flow alarm
|
|
Analyzer Type
|
|
O2 Analyzer
|
|
Primary Gas(es) to be Measured
|
|
Oxygen (O2)
|
|
Hazardous Area Rating Options
|
|
Control Cabinet - General Purpose, Non-Hazardous Detector Cabinet - NEMA7 Class 1 Division 1 Groups BCD
|
|
|
|
|
For continuous analysis of oxygen (O2) in process gas streams. Also recommended for other applications such as O2 enrichment of combustion air, flue gas analysis, oxygen deficiency analysis, and many more.
|
|
|
|
- Best value continuous O2 analyzer
- Bright digital readout
- Long life electrochemical O2 sensor
- Fast response (T90 - 6 to 8 seconds)
- Microprocessor control for push button calibration
- Easy-to-maintain modular layout
- Built in sample pump or pressure regulator
- 4-20mA outputs
|
|
|
|
- Hi/Low gas, low flow, and diagnostic alarms available
- Isolated analog, RS232, RS485, MODBUS, and Ethernet outputs available
- Sensors mounted in temperature controlled heated box to improve accuracy
- High temperature filters and probes
|
|
|
|
- Nitrogen for zero
- Air or analyzed calibration gas for span
|
|
|
|
|
|
|
|
|
|
|
|
|
|