Item # Model 481 D1 or D2, Model 481 D1 or D2, Carbon Monoxide Analyzer (infrared) - 481 Series; NEMA 4 cabinet with Hazardous Area Purge System
|
|
|
|
The Nova FLEXI-NOVA Series Platform has been designed for continuous gas measurements in applications and environments that are less intensive. Lab work, research, clean processes, pre-treated / pre-cleaned produced gases, and others, may benefit from the FLEXI-NOVA series.
For clean process measurements of % CO gas using an infrared detector. All sensors / detectors are temperature-controlled or temperature-compensated for maximum analytical stability. Easy calibration using touch-screen controls. Serial Output Package allows connection & data-logging to personal computers via a choice of USB / RS-232 / RS-485.
Cabinet: NEMA 4 cabinet with Hazardous Area Purge System; available for Class 1 Div1 or Class1 Div2 hazardous areas
|
|
|
|
|
Method of Detection
|
|
Single cell NDIR with no moving parts
|
|
Ranges Available
|
|
High ranges - any from 0-40 to 0-100% CO Standard ranges - 0-1.00, 2.00, 5.00, 10, 30% CO
|
|
Resolution
|
|
0.1% on most % ranges
|
|
Accuracy & Repeatability
|
|
±1-3% of full scale, depending on measurement range and application
|
|
Drift
|
|
Usually 2% of full scale per month or less, depending on range and application
|
|
Response Time (T-90)
|
|
Usually 20-30 seconds to 90% step change, depending on range and application
|
|
Ambient Temperature Range
|
|
40 to 104°F (4 to 40°C)
|
|
Linearity
|
|
Usually ±1.5% of full scale, depending on range and application
|
|
Size & Weight
|
|
NEMA 4: 61H x 51W x 31D cm (24"H x 20"W x 12"D) (not including purge panel & vent)
|
|
Power
|
|
115 VAC, 60 Hz 220 VAC, 50 Hz
|
|
Output Options
|
|
4-20 mA into 500 ohms non-isolated standard Isolated 4-20 mA, RS232, RS485 serial outputs
|
|
Alarms
|
|
High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating Low flow alarm
|
|
Analyzer Type
|
|
CO analyzer
|
|
Hazardous Area Rating Options
|
|
Class 1 Div 2 or Class 1 Div 1 Hazardous Area Ratings available
|
|
|
|
|
Light-duty analyzers for applications or environments that are less intensive. For continuous analysis of percent levels of carbon monoxide (CO) in process gas streams using an infrared detector.
|
|
|
|
- Detector is temperature-controlled or compensated for improved analytical stability
- Standard ranges, any between 0-30% CO
- High ranges available (up to 100%)
- Touch-screen display for gas readings
- Built-in sample pump or pressure regulator
- Non-isolated 4-20mA analog recorder output
|
|
|
|
- Hi/Low gas and low flow alarms available
- Serial output & data-logger package available
- Light-duty pre-filter & condensate removal
- Up to 6 other gases measured (depending on application)
- Cabinet cooling available
- Hazardous area purge systems; available for Class 1 Div1 or Div2 hazardous areas
|
|
|
|
- Easily Zero-checked on ambient air
- Span using bottled CO gas in N2
|
|
|
|
The FlexiNova 481 Series analyzers are designed for detection of CO in non-corrosive gas streams. All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova at 1-800-295-3771. In many cases, we are able to build an analyzer specific to your needs.
|
|
|
|
|
|
|
|
|
|
|
|