Item # Model 480N4, Model 480N4 PPM Carbon Monoxide Analyzer, Wall Mounted NEMA4 (IP65) Enclosure Rating
|
|
|
|
The Nova FLEXI-NOVA Series Platform has been designed for continuous gas measurements in applications and environments that are less intensive. Lab work, research, clean processes, pre-treated / pre-cleaned produced gases, and others, may benefit from the FLEXI-NOVA series. Depending on application, some light-duty sample conditioning features may be available. For clean process measurements of ppm-level CO gas using an electro-chemical sensor. All sensors / detectors are temperature-controlled or temperature-compensated for maximum analytical stability.
Easy calibration using touch-screen controls. Serial Output Package allows connection & data-logging to personal computers via a choice of USB / RS-232 / RS-485.
Cabinet: NEMA 4 rain-proof steel cabinet with window
|
|
|
|
|
|
|
Light-duty analyzers for applications or environments that are less intensive. For continuous analysis of up to 0-10,000 PPM carbon monoxide (CO) in process gas streams using an electrochemical sensor.
|
|
|
|
- Detector is temperature-controlled or compensated for improved analytical stability and fast response
- PPM range CO measurement by electrochemical sensor
- Touch-screen display for gas readings
- Built-in sample pump or pressure regulator
- Non-isolated 4-20mA analog recorder output
|
|
|
|
- Hi/Low gas and low flow alarms available
- Serial output & data-logger package available
- Light-duty pre-filter & condensate removal
- Up to 6 other gases measured (depending on application)
- Cabinet cooling available
|
|
|
|
- Nitrogen for zero
- Analyzed ppmCO calibration gas for span.
|
|
|
|
The electrochemical CO sensor is unsuitable with certain background gases such as hydrogen. Also, this cell requires that a small amount of O2 be present in the sample, or that it be metered into the sample. Consult Nova for each application.
|
|
|
|
|
|
|
|
|
|
|
|
|
|